Desa H) AND VM42(B, M36P Product Specifications, Introduction, Continued, Appliance Dimensions

Models: H)

1 28
Download 28 pages 27.94 Kb
Page 4
Image 4
PRODUCT SPECIFICATIONS

4

INTRODUCTION

Continued

Figure 1 - Appliance Dimensions CAUTION: Do not connect appliance before pressure testing gas piping. Damage to gas valve may result and an unsafe condition may be caused.

The appliance and itʼs individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.

GAS RATING - NATURAL

 

M36(B,H), VM36(B,H)

M42(B,H), VM42(B,H)

 

 

 

Max. Input Rating:

40,000 Btu/Hr

45,000 Btu/Hr

 

 

 

Manifold Pressure:

3.5 in. WC (.87 kPa)

3.5 in. WC (.87 kPa)

Minimum Supply Pressure:

4.5 in. WC (1.12 kPa)

4.5 in. WC (1.12 kPa)

 

 

 

Maximum Supply Pressure:

10.5 in. WC (2.66 kPa)

10.5 in. WC (2.66 kPa)

 

 

 

Orifice Size:

# 30

# 29

 

 

 

GAS RATING - PROPANE/LP

 

M36P(B,H), VM36P(B,H)

M42P(B,H), VM42P(B,H)

 

 

 

Max. Input Rating:

40,000 Btu/Hr

45,000 Btu/Hr

Manifold Pressure:

10 in. WC (2.49 kPa)

10 in. WC (2.49 kPa)

 

 

 

Minimum Supply Pressure:

11 in. WC (2.74 kPa)

11 in. WC (2.74 kPa)

 

 

 

Maximum Supply Pressure:

13 in. WC (3.23 kPa)

13 in. WC (3.23 kPa)

Orifice Size:

# 52

# 50

 

 

 

PRODUCT SPECIFICATIONS

A

F

For Use With 6"Ø Type B-1 Vent Pipe Only

Stand Off

Collar

E

D

7"

BCManual backgroundManual background

7"

 

 

 

Alternate

 

 

 

Gas Supply

 

 

 

 

 

 

 

 

Inlet

HEARTH AREA

H

DIMENSIONS

 

G

 

R

X

K

Outside Air

Kit Location I

(Optional) J

 

 

 

S

 

7"

T

Manual backgroundManual background P Manual backgroundManual background

Q

L

M

Glass Door

1.5"

13.5"

(Optional)

 

NO

W

Manual backgroundVManual backgroundManual background

 

Model 36

 

Model 42

 

Model 36

 

Model 42

 

Model 36

 

Model 42

 

 

 

 

 

 

A

29"

 

36"

I

40 1/4"

 

44 1/4"

Q

13 7/8"

 

14"

B

5/8"

 

5/8"

J

21"

 

24"

R

10 1/2"

 

12 1/2"

C

41"

 

48"

K

8"

 

9"

S

2 1/2"

 

2 1/2"

D

12"

 

14"

L

34 3/4"

 

42"

T

8 1/8"

 

8 1/8"

E

21 1/4"

 

23"

M

42"

 

49"

U

11"

 

12 3/4"

F

22 1/4" (24" w/o Brick)

 

29 1/4" (31" w/o Brick)

N

36"

 

40"

V

7"

 

7"

G

32 5/8" (34" w/o Brick)

 

39 1/2" (41 1/4" w/o Brick)

O

37"

 

41"

W

2 1/4"

 

2 1/4"

H

15 3/4" (16 3/4" w/o Brick)

 

17 3/4" (18 3/4" w/o Brick)

P

8 5/8"

 

10 1/2"

X

5"

 

4 1/2"

Figure 1 - Appliance Dimensions

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundFor more information, visit www.desatech.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

108795-01M

Page 4
Image 4
Desa H) AND VM42(B, H) AND VM42P(B, VM36P Product Specifications, Introduction, Continued, Appliance Dimensions