Desa M36P, H) Installation, Continued, COMBUSTION AIR KIT MODEL AK4 OPTIONAL, Appliance Enclosure

Models: H)

1 28
Download 28 pages 27.94 Kb
Page 14
Image 14
COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

14

INSTALLATION

Continued

5.Place the upper end of log 5 into the notch on the top inner right of log 1 (see Figure 31). Rest the lower end of log 5 on the middle grate finger as shown in Figure 32.

6.Place log 6 into the notch on the top right of log 1 (see Figure 31). Rest the lower end of log 6 on top of log 2B (see Figure 32).

As an option to enhance the look of the hearth, you may place the lava rock provided around the front and sides of the burner pan.

NOTICE: Do not put lava rock inside the burner pan or around the air mixer fitting. Placing lava rock inside the burner pan or blocking the openings of the propane/LP air-mixer could cause performance problems.

Log 5

Log 6

Log 1

Notch

Log 2B

Figure 31 - Installing Logs 5 and 6

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 33). Pull the handle to open or push to close.

APPLIANCE ENCLOSURE CAUTION: Air inlet ducts are not to terminate in attic space.

Screen Pocket

Air Kit

Handle

Figure 33 - Air Kit Handle Location

APPLIANCE ENCLOSURE

Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking.

If the appliance is mounted on a raised platform, it must be a con- tinuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the

total bottom of the appliance (see Figure 34).

 

 

 

 

 

 

 

Side

 

Side

 

 

 

 

Framing

 

Framing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 32 - Logs Installed for M42, M42P, VM42 and VM42P Models

Caulk HerePack Insulation

Figure 34 - Sealing Between Appliance and Framing