PRE-INSTALLATION

PREPARATION

Continued

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantle shelf maybe installed a maximum 12" (229 mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle compo- nents in relation to the fireplace opening.

12"

Combustible

(229mm)

Materials

Header

6" (152mm)

A

BSpacer

3" (76mm)

1 1/2" M42(B,H), M42P(B,H)

(38mm) Max.

 

 

TOP VIEW

 

 

Outer Surround

 

 

 

Combustible

 

 

 

Material May

 

 

 

Be Used

1 1/2" (38 mm)

 

SAFE

 

ZONE

Max.

3" (76 mm)

 

 

 

 

 

 

Max.

 

 

 

6" (152 mm)

 

 

 

Max.

 

 

 

A

 

Perpendicular

 

 

 

 

 

B

Wall

 

M36(B,H), M36P(B,H)

M42(B,H), M42P(B,H)

 

VM36(B,H), VM36P(B,H)

VM42(B,H), VM42P(B,H)

A

9" (229 mm)

 

6" (152 mm)

B

12" (305 mm)

 

9" (229 mm)

Figure 6 - Side Clearances - Top View (Cross Section)

 

M36(B,H), M36P(B,H)

M42(B,H), M42P(B,H)

 

VM36(B,H), VM36P(B,H)

VM42(B,H), VM42P(B,H)

A

14" (356 mm)

15" (381 mm)

B

8" (203 mm)

9" (229 mm)

 

 

 

Figure 5 - Mantel Clearances - Side View (Cross Section)