SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom, unless installed as a vented appli- ance. See Installing Damper Clamp Accessory for Vented Operation, page 12 (Remote-Ready Models Only).

5.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating heater.

6.Do not burn solid-fuel in a masonry or UL127 factory-built fireplace in which a vent-free room heater is installed.

7.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

8.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 26.

9.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture.

10.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if enough fresh air is not available. See Air for Combustion and Ventilation, page 6. If heater keeps shutting off, see Troubleshooting, page 28.

11.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not use this heater to cook food or burn paper or other objects.

13.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

14.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

15.Turn heater off and let cool before servicing, installing or repairing. Make sure the selector switch is in the OFF position (Remote-Ready Models Only). Only a qualified service person should install, service or repair heater.

16.Make sure the selector switch is in the OFF position when you are away from home for long periods of time (Remote-Ready Models Only).

17.Remote-ready heaters must not be connected to any external electrical source.

18.Operating heater above elevations of 4,500 feet may cause pilot outage.

19.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity (propane/LP units only).

20.Provide adequate clearances around air openings.

Unpacking

CAUTION: Do not remove the dataplatesfromthegrateassembly. The data plates contain important warranty and safety information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base as- sembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

www.desatech.com119426-01A

Page 4
Image 4
Desa VUL18, VUL24, VUL30, P)T, P)R, HRB3624, HRB3930/3924 installation manual Unpacking

VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T, VUL18, VUL24, VUL30, HRB3930/3924, HRB3624, P)R specifications

Desa P)R, HRB3624, HRB3930/3924, VUL18, VUL24, VUL30, VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, and HR B3624T are part of an innovative product line designed to enhance efficiency and performance across various applications. These models showcase cutting-edge technologies and features that cater to diverse user needs.

The Desa P)R series is renowned for its robustness and reliability. Engineered with advanced materials, these models offer superior durability, making them suitable for both industrial and commercial environments. Their high-performance capabilities ensure they can handle demanding tasks without compromise.

The HRB3624 and HRB3930/3924 series provide powerful solutions with enhanced energy efficiency. Equipped with state-of-the-art motors and optimized designs, they deliver exceptional output while minimizing energy consumption. These models feature smart technology that adjusts performance based on workload, maximizing efficiency and prolonging equipment life.

VUL series, including VUL18, VUL24, and VUL30, is characterized by their versatility and user-friendly interface. These products incorporate intuitive controls, allowing for easy operation across various settings. The VUL series also features modular designs, enabling easy upgrades and maintenance to keep pace with changing requirements.

For those requiring specialized functions, the VUL 18R, VUL24R, and VUL30R models offer enhanced performance with refined specifications. These editions are optimized for high precision and are particularly suited for applications where accuracy is paramount.

The HR B3930 and HR 3924R models stand out due to their compact design without sacrificing power. Perfect for space-constrained environments, they provide a combination of high efficiency and powerful output, making them ideal for modern facilities.

The CRB3624T, VUL 18T, VUL24T, and VUL30T series incorporate advanced technology for temperature control and monitoring, ensuring optimal performance under varying conditions. These models are equipped with intelligent sensors that provide real-time feedback, allowing users to make informed adjustments.

Finally, the HR B3624T emphasizes thermal efficiency, boasting features that significantly reduce overheating risks and enhance safety. This series prioritizes user safety alongside effective performance.

In conclusion, the comprehensive features and technologies of the Desa P)R series, along with HRB and VUL models, position them as leading choices for industries seeking reliable, efficient, and versatile solutions.