Installation | |
| Continued |
Propane/LP | Equipment |
Supply Tank | Shutoff Valve |
| Thermostat Gas |
| Valve or Control |
| Valve Location |
Figure 18 - Checking Gas Joints
(Propane/LP Only)
Equipment
Shutoff Valve
Gas Meter
Thermostat Gas
Valve or Control
Valve Location
Figure 19 - Checking Gas Joints (Natural
Gas Only)
Installing optional remote accessories
Installing Remote Receiver
Remote control accessories are available sepa- rately (see Accessories, page 42).
1.If unit is already installed in fireplace, continue with these instructions. If unit has not been installed in fireplace, go to step 6 and continue installation of remote accessory.
WARNING: Turn off heater and let cool before handling any part of heater. Make sure gas is turned of to unit.
2.Carefully remove logs and set aside.
3.Locate mounting screws on sides of heater base assembly and remove screws. Set screws aside for reinstallation.
4.Disconnect gas line from heater base as shown in Figure 11 or 12, page 13.
WARNING: A qualified ser- vice person must connect and disconnect gas to heater. Follow all local codes.
5.Remove heater base from fireplace.
6.Install receiver bracket to base with phillips screws provided in hardware kit as shown in Figure 20.
7.Disconnect jumper wire from control valve at TPTH and TH locations (see Figure 21).
8.Install remote receiver into receiver bracket using pads and push button clips provided with receiver (see Figure 22).
Phillips
Screws
Remote Receiver Bracket
Figure 20 - Installing Remote Receiver
Bracket
| Jumper |
Control Valve | Wire |
|
Figure 21 - Disconnecting Jumper Wire
From Control Valve
Battery
Clip
Push | Pad | Terminal |
| ||
Button | Bracket | Wires |
Clips |
|
Figure 22 - Installing Remote Receiver
www.desatech.com | 17 |