CHECK GAS TYPE

Installation

Continued

Figure 4 - Minimum Clearance for CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

Important: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.

CHECK GAS TYPE

Use the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

Combustible to Wall WARNING: This appliance is equipped for natural or pro- pane/LP gas. Field conversion is not permitted.

INSTALLATION AND CLEARANCES For Vent-Free Operation

Manual background WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.

MINIMUM FIREPLACE CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

18", 24", 30"

Side Wall

16"

 

 

Ceiling

42"

 

 

Floor

5"

 

 

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Log

 

 

Front

Rear*

Size

Height

Depth

Width

Width

 

 

 

 

 

18"

17"

14"

20"

14"

24"

17"

14"

26"

18"

30"

17"

14"

32"

22"

*Measured at 14" depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127- listed manufactured fireplace or listed vent-free firebox.

Minimum Clearances For Side

Combustible Material, Side Wall and

Ceiling

A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace cabinet (see Figure 4).

Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42".

Example

*

*Minimum 16" from Side Wall

Figure 4 - Minimum Clearance for

Combustible to Wall