Desa VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T

Models: VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T VUL18, VUL24, VUL30 HRB3930/3924 HRB3624 P)R P)T

1 44
Download 44 pages 40.12 Kb
Page 5
Image 5
Product

Product

Identification

Model CRB and

HRB Series Logs

Ignitor

 

Control Knob

Base

 

Assembly

Model VUL

Rear Burner

 

Series Logs

 

State of Massachusetts: The installa- tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

Optional Remote

Control Accessories

There are four optional remote controls that

can be purchased separately for Remote-Ready

Models Only:

 

 

wall switch

hand-held ON/OFF remote

wall thermostat

hand-held thermostat remote

See Accessories, page 42.

The wall thermostat or hand-held thermostat may not be used where vented decorative listing is required.

Ignitor

 

 

Control

 

 

Remote Knob

Flame

Base

Control

Adjustment

Assembly

(Optional)

Knob

 

Figure 1 - Product Identification

Local Codes

Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Product Features

Operation

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for vent- free operation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANSI Z21.60) product by opening the flue damper (Non-Thermostat Models Only).

Safety Device

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Electronic Ignition System

This heater has an electronic ignitor to light heater fuel supply.

119426-01Awww.desatech.com

Page 5
Image 5
Desa VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T, P)T Product Identification