AIR FOR COMBUSTION

AND VENTILATION

Continued

Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless pas- sageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height =__________cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

___________ (volume of space) x 20 = (Maxi- mum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free fireplace

____________ Btu/Hr

Gas water heater*

____________ Btu/Hr

Gas furnace

____________ Btu/Hr

Vented gas heater

____________ Btu/Hr

Gas fireplace logs

____________ Btu/Hr

Other gas appliances*

+__________ Btu/Hr

Total

=__________ Btu/Hr

*Do not include direct-vent gas appliances. Di- rect-vent draws combustion air from the outdoors and vents to the outdoors.

Example:

 

40,000

 

Gas water heater

 

Btu/Hr

Vent-free fireplace

+

33,000

Btu/Hr

Total

=

73,000

Btu/Hr

4. Compare the maximum Btu/Hr the space can

support with the actual amount of Btu/Hr used.

__________ Btu/Hr (maximum the space can support)

A.Rework worksheet, adding the space of an adjoin- ing room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.

B.Vent room directly to the outdoors. See Ventila- tion Air From Outdoors, page 8.

C.Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an un- confined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be oper- ated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA54 Section 5.3 or applicable local codes.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

__________Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space

can support)

73,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maxi- mum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

Ventilation

 

Grills Into

 

Adjoining

Or

Room,

Remove

Option 1

Door into

 

 

Adjoining

 

Room,

 

Option

 

3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

12"

Figure 2 - Ventilation Air from Inside Building

119426-01Awww.desatech.com

Page 7
Image 7
Desa P)R, P)T, HRB3624, HRB3930/3924, VUL18, VUL24, VUL30 Ventilation AIR, Ventilation Air From Inside Building

VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T, VUL18, VUL24, VUL30, HRB3930/3924, HRB3624, P)R specifications

Desa P)R, HRB3624, HRB3930/3924, VUL18, VUL24, VUL30, VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, and HR B3624T are part of an innovative product line designed to enhance efficiency and performance across various applications. These models showcase cutting-edge technologies and features that cater to diverse user needs.

The Desa P)R series is renowned for its robustness and reliability. Engineered with advanced materials, these models offer superior durability, making them suitable for both industrial and commercial environments. Their high-performance capabilities ensure they can handle demanding tasks without compromise.

The HRB3624 and HRB3930/3924 series provide powerful solutions with enhanced energy efficiency. Equipped with state-of-the-art motors and optimized designs, they deliver exceptional output while minimizing energy consumption. These models feature smart technology that adjusts performance based on workload, maximizing efficiency and prolonging equipment life.

VUL series, including VUL18, VUL24, and VUL30, is characterized by their versatility and user-friendly interface. These products incorporate intuitive controls, allowing for easy operation across various settings. The VUL series also features modular designs, enabling easy upgrades and maintenance to keep pace with changing requirements.

For those requiring specialized functions, the VUL 18R, VUL24R, and VUL30R models offer enhanced performance with refined specifications. These editions are optimized for high precision and are particularly suited for applications where accuracy is paramount.

The HR B3930 and HR 3924R models stand out due to their compact design without sacrificing power. Perfect for space-constrained environments, they provide a combination of high efficiency and powerful output, making them ideal for modern facilities.

The CRB3624T, VUL 18T, VUL24T, and VUL30T series incorporate advanced technology for temperature control and monitoring, ensuring optimal performance under varying conditions. These models are equipped with intelligent sensors that provide real-time feedback, allowing users to make informed adjustments.

Finally, the HR B3624T emphasizes thermal efficiency, boasting features that significantly reduce overheating risks and enhance safety. This series prioritizes user safety alongside effective performance.

In conclusion, the comprehensive features and technologies of the Desa P)R series, along with HRB and VUL models, position them as leading choices for industries seeking reliable, efficient, and versatile solutions.