VENTING INSTALLATION

Continued

Horizontal Termination Configurations

Figures 29 through 31 show different configurations for venting with horizontal termination. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. Seal all connections with high temperature silicone sealant (outer pipe only) as specified in the second warning statement on page 12. All horizontal piping runs require 1/4" rise per 12" of horizontal run.

Horizontal Venting

Vertical (V) Horizontal (H)

52" min.

26" max.

63" min.

49" max.

86" min.

96" max.

91" min.

20' max.

.

VENTING INSTALLATION

Installation for Horizontal Termination (Cont.)

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1)

Horizontal (H1) +

6' min.

4' max.

Horizontal (H2)

8' max.

7' min.

6' max.

12' max.

8' min.

8' min.

20' max.

20' max.

8' max.

20' max.

15

Figure 30 - Horizontal Termination Configuration for Venting

Using Two 90° Elbows Figure 29 - Horizontal Termination Configuration for Venting

Using One 90° Elbow

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

6' min.

4' max.

7' min.

6' max.

8' min.

10' max.

20' max.

12' max.

Figure 31 - Horizontal Termination Configuration for Venting

Using Two 90° Elbows with Termination at 90° with Stove

For morevisit www..com

107304-01D

Page 15
Image 15
Desa SDVBNC, SDVBPC installation manual Horizontal Termination Configurations, Horizontal Venting