INSTALLATION
Continued
2.Remove 4 screws from upper louver (see Figure 15). Save these screws.
3.Pull upper louver straight out from the cabinet. Be careful not to scratch the paint. Set louver aside.
4.Open lower louver door by swinging door down (see Figure 15).
Top
Louver
Lower Louver
Figure 15 - Removing Top Louver and
Opening Bottom Louver
Installing Blower Accessory
CAUTION: Label all wires prior to disconnection when ser- vicingcontrols.Wiringerrorscan cause improper and dangerous operation.
6.Route the wire harness through the hole in left side of baffle and between firebox wrapper and outer casing.
7.Insert the 4 wire harnesses from behind the remote/blower bracket through hole in rear of bracket with bushing and through the left rectan- gular hole to front of fireplace (see Figure 16).
8.Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.
9.Install the switch plate on the remote/blower bracket with 2 #10 screws provided (see Fig- ure 18, page 15). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 16). Plug fan kit into
10.Reinstall upper louver beginning with bottom screws (see Figure 15). Close lower louver door.
Blower | Wiring Routing | ||
Bracket | Wire Hole in Baffle | Blower | |
Assembly | Harness | ||
Mounting | |||
Screw |
| ||
| Holes |
CAUTION: Verify proper op- eration after servicing.
Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is
1. Install snap bushings found in blower kit into hole in left side of outer casing and into one of the holes in rear of remote/blower bracket.
2. Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly.
3. Note the wire locations on back of AUTO/ OFF/ON switch. The terminals on back of switch are numbered 1, 2 and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 16).
4. Carefully disconnect green and white wires at their insulated connectors (see Figure 17).
5. In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket as- sembly to the outer casing with 4 #10 screws provided (see Figure 16).
Switch | Power | |
| Cord | |
3 |
| |
2 |
| |
1 |
| |
Switch |
| |
Plate | Remote/ | |
Wire | ||
Blower | ||
Harness Bracket Lower Louver Door |
Figure 16 - Installing Blower Bracket Assembly (Remote-Ready Unit Shown)
Fan Switch
(Auto/Off/On)
1Auto
|
| Off | 2 |
|
|
|
|
|
| 3 | Blue | Thermostat | |
|
|
|
|
| ||
|
|
| On |
| Switch | |
|
|
|
| (N.O.) | ||
|
|
|
|
|
| Blue |
110/115 | Red |
| Blower | |||
| V.A.C. |
|
|
| Motor | |
|
| Black |
|
|
| Red |
|
|
|
|
| ||
|
| White |
|
|
| White |
|
| Green |
|
|
| Green |
Figure 17 - Wiring Diagram For Blower
Accessory Standard Installation
14 | www.desatech.com |