Desa VDCFTNA installation manual Remove 4 screws from upper louver see . Save these screws

Models: VDCFTNA

1 44
Download 44 pages 131 b
Page 14
Image 14

INSTALLATION

Continued

2.Remove 4 screws from upper louver (see Figure 15). Save these screws.

3.Pull upper louver straight out from the cabinet. Be careful not to scratch the paint. Set louver aside.

4.Open lower louver door by swinging door down (see Figure 15).

Top

Louver

Lower Louver

Figure 15 - Removing Top Louver and

Opening Bottom Louver

Installing Blower Accessory

CAUTION: Label all wires prior to disconnection when ser- vicingcontrols.Wiringerrorscan cause improper and dangerous operation.

6.Route the wire harness through the hole in left side of baffle and between firebox wrapper and outer casing.

7.Insert the 4 wire harnesses from behind the remote/blower bracket through hole in rear of bracket with bushing and through the left rectan- gular hole to front of fireplace (see Figure 16).

8.Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.

9.Install the switch plate on the remote/blower bracket with 2 #10 screws provided (see Fig- ure 18, page 15). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 16). Plug fan kit into 120-Volt grounded power supply and test operation. Note: When switch is in the AUTO position, the fan will start after the fireplace has run for a few moments. The fan will continue to run for several moments after the fireplace has been turned off. When switch is in the ON position, the fan will run until turned to OFF.

10.Reinstall upper louver beginning with bottom screws (see Figure 15). Close lower louver door.

Blower

Wiring Routing

Bracket

Wire Hole in Baffle

Blower

Assembly

Harness

Mounting

Screw

 

 

Holes

CAUTION: Verify proper op- eration after servicing.

Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation, page 15.

1. Install snap bushings found in blower kit into hole in left side of outer casing and into one of the holes in rear of remote/blower bracket.

2. Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly.

3. Note the wire locations on back of AUTO/ OFF/ON switch. The terminals on back of switch are numbered 1, 2 and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 16).

4. Carefully disconnect green and white wires at their insulated connectors (see Figure 17).

5. In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket as- sembly to the outer casing with 4 #10 screws provided (see Figure 16).

Switch

Power

 

Cord

3

 

2

 

1

 

Switch

 

Plate

Remote/

Wire

Blower

Harness Bracket Lower Louver Door

Figure 16 - Installing Blower Bracket Assembly (Remote-Ready Unit Shown)

Fan Switch

(Auto/Off/On)

1Auto

 

 

Off

2

 

 

 

 

 

 

3

Blue

Thermostat

 

 

 

 

 

 

 

 

On

 

Switch

 

 

 

 

(N.O.)

 

 

 

 

 

 

Blue

110/115

Red

 

Blower

 

V.A.C.

 

 

 

Motor

 

 

Black

 

 

 

Red

 

 

 

 

 

 

 

White

 

 

 

White

 

 

Green

 

 

 

Green

Figure 17 - Wiring Diagram For Blower

Accessory Standard Installation

14

www.desatech.com

113133-01C

Page 14
Image 14
Desa VDCFTNA installation manual Remove 4 screws from upper louver see . Save these screws, Installing Blower Accessory