TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Fireplace produces unwanted

1. Fireplace burning vapors from

1.

Open window to ventilate

odors

 

paint, hair spray, glues, clean-

 

room. Stop using odor caus-

 

 

 

ers, chemicals, new carpet,

 

ing products while fireplace

 

 

 

etc. (See IMPORTANT state-

 

is running

 

 

2.

ment above)

2.

Refill supply tank (propane/LP

 

 

Low fuel supply (propane/LP

 

 

3.

only)

3.

only)

 

 

Gas leak. See Warning state-

Locate and correct all leaks

 

 

 

ment at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 17)

 

 

 

 

 

 

Fireplace shuts off in use (ODS

1. Not enough fresh air is

1.

Open window and/or door for

operates)

2.

available

2.

ventilation

 

 

Low line pressure

Contact local natural or pro-

 

 

3.

O D S / pi l o t i s pa rt i a l l y

3.

pane/LP gas company

 

 

Clean ODS/pilot (see Cleaning

 

 

 

clogged

 

and Maintenance, page 27)

 

 

 

 

 

Gas odor even when control

1. Gas leak. See Warning

1.

Locate and correct all leaks

 

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

 

2.

Control valve defective

2.

tions, page 17)

 

 

Replace control valve

 

 

 

 

 

Gas odor during combustion

1. Foreign matter between con-

1.

Take apart gas tubing and

 

 

2.

trol valve and burner

2.

remove foreign matter

 

 

Gas leak. See Warning

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 17)

32