Desa VDCFTNA Operating Fireplace, To Turn OFF GAS To Appliance, Thermostat Control Operation

Models: VDCFTNA

1 44
Download 44 pages 131 b
Page 22
Image 22

OPERATING FIREPLACE

Continued

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, page 29. Also, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise

to desired heating level. The burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor

Control

Button

 

Knob

Figure 36 - Control Knob In The OFF

 

Position

 

Ignitor

Thermocouple

Electrode Pilot Burner

Figure 37 - Natural Gas Pilot

Ignitor

Thermocouple

Pilot Burner

Electrode

 

Figure 38 - Propane/LP Gas Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise to the OFF position.

2. Turn off all electric power to the appliance (if applicable) if service is to be performed.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat used on this fireplace senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room tem- perature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb measures the air near the fireplace cabinet. This may not always agree with room temperature (de- pending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your fireplace will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, beginning on page 21.

2.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.

22

www.desatech.com

113133-01C

Page 22
Image 22
Desa VDCFTNA Operating Fireplace, To Turn OFF GAS To Appliance, Thermostat Control Operation, Manual Lighting Procedure