VENTING INSTALLATION
Continued
Vertical Venting
V = 30' max.
RVF Kit Shown
45° Starter Elbow
Required
Figure 31 - Vertical Rigid Venting Configuration With No Horizontal Run
HIGH ALTITUDE INSTALLATION
Your Vanguard direct-vent fireplace has been CSA tested and approved for operation at altitudes in the USA from 0-2000 ft. and in Canada from 0-45000 ft.
When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice for your location.
For assistance with any high altitude installation contact DESA International’s Technical Service Department at 1-866-672-6040.
PARTS LISTS FOR VENTING KITS AND COMPONENTS
*NOTICE: The 7PA-47-6 pipe adaptor is required for use with the DESA 7 1/4" x 4 1/4" pipe. It MUST be attached at the vent collar prior to assembly.
Vanguard Rigid Venting
Number Description
P47-6 6" Galvanized Coaxial Pipe Section
P47-12 12" Galvanized Coaxial Pipe Section
P47-24 24" Galvanized Coaxial Pipe Section
P47-36 36" Galvanized Coaxial Pipe Section
P47-48 48" Galvanized Coaxial Pipe Section PA47-712 Adjustable 7"-12" Galvanized Coaxial Pipe Section VKG-47 Galvanized Ground Floor Vent Kit
Includes: 45º Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, and 16 Screws
VKB-47 Basement Galvanized Vent Kit
Includes: 45º Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, 4' Pipe, 90° Elbow, and 20 Screws
VKS-47 Snorkel Galvanized Kit
Includes: 45º Elbow, 7"-12" Adjustable Pipe, Wall Firestop, 36" Snorkel Termination, 4' Pipe, 90° Elbow, and 26 Screws
VKR-47 Roof Rigid Vent Kit
Includes: 45º Elbow, 7"-12" Adjustable Pipe, Flue Re- strictor, Vertical High Wind Termination, 2' Pipe, 4' Pipe, Firestop Plate, Roof Flashing (0/12-6/12), and 18 Screws
VKC-47 Corner Vent Kit
Includes: 45º Elbow, 7"-12" Adjustable Pipe, Horizon- tal Termination, 6" Pipe, 90° Elbow, Wall Firestop, and 18 Screws
DESA International Elbows
Number Description
E47-45 45° Elbow, Galvanized
E47-90 90° Elbow, Galvanized
DESA International Terminations
Number Description
HT-47 Horizontal Round Galvanized Termination
HTS-47 Horizontal Square Galvanized Termination
VT-47 Vertical Round Galvanized Termination
ST-47-14 14" Snorkel Galvanized Termination
ST-47-36 36" Snorkel Galvanized Termination