20

VENTING INSTALLATION

Installing Log Set (Cont.)

Decorative Facing

PILOT ASSEMBLY ADJUSTMENT BURNER FLAME ADJUSTMENT

INSTALLATION

Continued

9.Place logs “B” as shown in Figure 45. Lift the end of log “A” that will be propped up and place log “B” under it. At the same time, the other side of log “B” is placed over the other log “A”. Repeat procedure for the other log “B”.

10.Take twigs “C” (shaped like a “Y”) and place them as shown in Figure 46.

11.Take twigs “D” (bent twig) and place them as shown in Figure 46.

12.Place twig “E” across the top of logs “B” a shown in Figure 46.

13.When finished installing the logs, close the glass doors while making certain that the safety door switch is fully depressed by the door frame before securing the four (4) spring loaded latches.

14.Replace the louvers in reverse order with the grilles pointing in the down position.

WARNING: Improper installation, adjustment, al- teration, service, or maintenance can cause injury or property damage. Refer to this manual. For assis- tance or additional information, consult a qualified installer, service agency, or gas supplier.

 

 

Left

 

Back

 

A

Front

B

B

 

 

 

 

 

 

 

A

 

Right

Figure 45 - Installing Logs “B ” (Top View)

 

 

Left

 

 

D

 

C

 

 

 

Back

 

E

Front

 

 

 

C D

Right

Figure 46 - Installing Twigs “C, D, E ” (Top View)

DECORATIVE FACING

Anynoncombustiblematerialmaybeusedforfacing(glass,tile,brick,etc.) as long as the proper clearances are observed (see Clearances, page 5). IMPORTANT:Louvered openings must not be obstructed, and upper and lower panels must remain removable for servicing. Use only heat-resistant, noncombustible mortar or adhesive when securing facing material.

Note: Combustible material, such as wood, that has been fireproofed is not considered noncombustible.

PILOT ASSEMBLY

ADJUSTMENT

The pilot assembly is factory preset for the proper flame height. Alteration to these settings may have occurred during shipping and handling. If this is the case, some minor adjustment may be neces- sary and should be done by a qualified technician. To access the pilot assembly, the glass door must be opened. The proper settings for the thermopile height should be at a distance of 3/8" (.95cm) to 1/2" (1.3cm) from the pilot flame as shown in Figure 47.

1/8"

 

(0.3cm)

3/8" - 1/2"

 

 

(.95cm-1.3cm)

Figure 47 - Correct Pilot Flame Pattern

BURNER FLAME ADJUSTMENT

The air shutter, located at the underside of the main burner (see Figure 48), has been factory preset to the proper air-to-gas ratio which results in an even, clean burning flame across the burner (see Figure 49). If readjustment is necessary, you can restore the proper air-to-gas ratio by loosening the air shutter screw and rotating the air shutter until the proper flame setting is achieved (the shutter's normal setting is “full opened”. Do not forget to retighten the air shutter screws.

Air Shutter

Orifice

Burner

 

 

 

 

Venturi Tube

Firebox Bottom

Burner Gas Line

 

Figure 48 - Connecting Venturi and Orifice

 

CORRECT

Long, Blue Flame with Yellow Tips

INCORRECT CLOSE SHUTTER Short, Sharp, Blowing Flame

INCORRECT

OPEN SHUTTER Long, Uneven, Yellow Flame

Figure 49 - Burner Flame Patterns

For..com

106918-01B

Page 20
Image 20
Desa VDDVF36PN/PP, VDDVF36STN/STP installation manual Pilot Assembly Adjustment, Burner Flame Adjustment, Decorative Facing

VDDVF36PN/PP, VDDVF36STN/STP specifications

The Desa VDDVF36STN/STP and VDDVF36PN/PP represent a range of advanced heating solutions designed to meet modern demands for efficiency, comfort, and versatility. These models are distinguished by their exceptional features and cutting-edge technologies, making them suitable choices for both residential and commercial applications.

One of the primary features of the Desa VDDVF series is its innovative design that prioritizes energy efficiency. Designed with high-performance materials, these units are equipped to reduce energy consumption while providing powerful heating output. This ensures that users can enjoy a warm and comfortable environment without incurring excessive energy costs.

The VDDVF series utilizes advanced variable-speed technology, allowing for precise temperature control. This technology not only enhances comfort but also contributes to quieter operation, allowing users to enjoy a serene atmosphere. The variable-speed blower ensures that warm air is distributed evenly throughout the room, mitigating cold spots and maximizing comfort.

Another notable characteristic of the Desa VDDVF36 models is their adaptability. With options for either natural gas or propane, these heaters can meet a variety of user preferences and installation requirements. This flexibility makes them suitable for different environments, from cozy family homes to larger commercial spaces.

Safety is a priority in the design of the VDDVF series. Each unit is equipped with a range of safety features, including a built-in oxygen depletion sensor, which automatically shuts off the heater if oxygen levels drop to unsafe levels. This feature, along with a robust construction, ensures peace of mind for users.

In terms of aesthetics, the VDDVF36STN/STP and VDDVF36PN/PP boast a sleek and modern appearance that can enhance any interior decor. With customizable options, users can select finishes and styles that complement their space.

Overall, the Desa VDDVF36STN/STP and VDDVF36PN/PP epitomize the convergence of comfort, efficiency, and safety. Their advanced technologies and user-friendly features make these heating solutions an excellent investment for anyone seeking reliable warmth in their living or working environment. As energy efficiency continues to be a focal point in today’s world, the Desa VDDVF series stands out as a leading choice for those looking to balance performance with sustainability.