GENERAL VENTING

Location Of Vent Termination (Cont.)

GENERAL VENTING Continued

N

N

D

E V

B L

 

C

 

 

Fixed

V

 

Closed

 

 

F

Openable

 

V

 

Openable

B

Fixed

Closed

H

V

B

I

G

B

B

V J X

G

A

M

V

K X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

 

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5cm) minimum]

B= clearance to window or door that may be opened

[12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the center-line of the terminal [18 inches (45.7cm) minimum]

E= clearance to unventilated soffit [12 inches (30.5cm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (30.5cm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]

L= clearance above paved side-walk or a paved driveway located on public property [*84 inches (213.4cm) minimum]

M= clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ]

N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow

the current National Fuel Gas Code, ANSI Z223.1

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

A

 

A = 6" (15.2cm)

 

V

Outside Corner

V

B B = 6" (15.2cm)

Recessed Location

D

C

C

E

V

Balcony with No Side Wall

G

V

G = Combustible 24" (61cm) Noncombustible 18" (45.7cm)

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (96.5cm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)

Figure 13 - Minimum Clearances for Vent Terminations

For..com

106918-01B

Page 8
Image 8
Desa VDDVF36PN/PP, VDDVF36STN/STP installation manual General Venting

VDDVF36PN/PP, VDDVF36STN/STP specifications

The Desa VDDVF36STN/STP and VDDVF36PN/PP represent a range of advanced heating solutions designed to meet modern demands for efficiency, comfort, and versatility. These models are distinguished by their exceptional features and cutting-edge technologies, making them suitable choices for both residential and commercial applications.

One of the primary features of the Desa VDDVF series is its innovative design that prioritizes energy efficiency. Designed with high-performance materials, these units are equipped to reduce energy consumption while providing powerful heating output. This ensures that users can enjoy a warm and comfortable environment without incurring excessive energy costs.

The VDDVF series utilizes advanced variable-speed technology, allowing for precise temperature control. This technology not only enhances comfort but also contributes to quieter operation, allowing users to enjoy a serene atmosphere. The variable-speed blower ensures that warm air is distributed evenly throughout the room, mitigating cold spots and maximizing comfort.

Another notable characteristic of the Desa VDDVF36 models is their adaptability. With options for either natural gas or propane, these heaters can meet a variety of user preferences and installation requirements. This flexibility makes them suitable for different environments, from cozy family homes to larger commercial spaces.

Safety is a priority in the design of the VDDVF series. Each unit is equipped with a range of safety features, including a built-in oxygen depletion sensor, which automatically shuts off the heater if oxygen levels drop to unsafe levels. This feature, along with a robust construction, ensures peace of mind for users.

In terms of aesthetics, the VDDVF36STN/STP and VDDVF36PN/PP boast a sleek and modern appearance that can enhance any interior decor. With customizable options, users can select finishes and styles that complement their space.

Overall, the Desa VDDVF36STN/STP and VDDVF36PN/PP epitomize the convergence of comfort, efficiency, and safety. Their advanced technologies and user-friendly features make these heating solutions an excellent investment for anyone seeking reliable warmth in their living or working environment. As energy efficiency continues to be a focal point in today’s world, the Desa VDDVF series stands out as a leading choice for those looking to balance performance with sustainability.