12

VENTING INSTALLATION

Installation for Horizontal Termination (Cont.)

VENTING INSTALLATION

Continued

Horizontal Termination Configurations

Figures 21 through 23 show different configurations for venting with horizontal termination. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 9. All horizontal terminations require 1/4" rise per 12" of horizontal run.

FGFVK Vent Kit Shown

Note: The 30° Starter Elbow Must Be Discarded and Replaced with a 45° Starter Elbow.

Horizontal Venting

Vertical (V)

Horizontal (H)

49.5" min.

15" max.

(45° elbow, 1' vertical pipe, 90° elbow)

61.5" min.

34" max.

73.5" min.

58" max.

85.5" min.

10' max.

102.5" min.

20' max.

45° Starter

 

Elbow Required

 

Horizontal Venting

See information in Figure 21 for Vertical(V) and Horizontal(H) maximums and minimums. The same amounts apply for flexible venting.

Figure 22 - Horizontal Termination Using Flexible Venting

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

5' min.

4' max.

6' min.

8' max.

7' min.

10' max.

8' min.

15' max.

20' max.

20' max.

Figure 21 - Horizontal Termination Configuration for Rigid

Venting Using One 90° Elbow

45° Starter

Elbow

Required

Figure 23 - Horizontal Termination Configuration for Rigid

Venting Using Two 90° Elbows with Termination at 90° with

Fireplace

For..com

105706-01B