VENTING INSTALLATION

Installation for Vertical Termination (Cont.) High Altitude Installation Parts Lists for Venting Kits and Components

15

VENTING INSTALLATION

Continued

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Note: Vertical (V1) +

Vertical (V2) = 20' max.

45° Starter Elbow

Required

Figure 30 - Vertical Rigid Venting Configuration Using Two 90° Elbows

Vertical Venting

V = 30' max.

RVF Kit Shown

45° Starter Elbow

Required

Figure 31 - Vertical Rigid Venting Configuration With No Horizontal Run

HIGH ALTITUDE INSTALLATION

Your Vanguard direct-vent fireplace has been CSA tested and approved for operation at altitudes in the USA from 0-2000 ft. and in Canada from 0-45000 ft.

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA International’s Technical Service Department at 1-866-672-6040.

PARTS LISTS FOR VENTING KITS AND COMPONENTS

*NOTICE: The 7" x 30° Elbow supplied with kits CVK, BVK, SVK, and RVF cannot be used. It MUST be replaced with a 7" x 45º Starter Elbow (D2060).

Vanguard Rigid Venting

Number

Description

*CVK

Corner Vent Kit

 

Includes: 7" x 30º Elbow, 7" x 90º Elbow, 7" Adjustable

 

Galvanized Pipe (7-12"), 6" Pipe, Wall Thimble, Hori-

 

zontal Termination, RTV Silicone and 20 Screws

*BVK

Basement Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x

 

90° Elbow, 7" Adjustable Galvanized Pipe (7-12"),

 

Wall Thimble, Horizontal Termination, RTV Silicone

 

and 20 Screws

*SVK

Snorkel Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x

 

90° Elbow, 7" Adjustable Galvanized Pipe (7-12"),

 

Wall Thimble, 36" Snorkel Termination, RTV Silicone

 

and 28 Screws

*RVF

Roof Rigid Vent Kit

 

Includes: Flue Restrictor, Storm Collar, 7" x 30° Elbow,

 

7" x 4' Galvanized Pipe, 7" x 2' Galvanized Pipe, 7"

 

Adjustable Galvanized Pipe (7-12"), Firestop Support,

 

Roof Flashing, RTV Silicone, Vertical Termination,

 

and 26 screws

For morevisit www..com