Desa VDVF36PN/PP Replacement Parts Service Hints, Technical Service, Wiring Diagram

Models: VDVF36PN/PP VDVF36STN/STP

1 34
Download 34 pages 29.74 Kb
Page 24
Image 24

24

REPLACEMENT PARTS WIRING DIAGRAM SERVICE HINTS TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at 1-866-672-6040 for referral information.

When calling DESA International, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

burner will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Ser- vice Department at 1-866-672-6040. When calling, please have your model and serial numbers ready.

You can also visit DESA International’s Technical Services web site at www.desatech.com.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International at 1-866-672- 6040 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

WIRING DIAGRAM

 

Piezo Ignitor

Pilot

Piezo Ignitor

Do Not

 

 

Thermocouple

Thermopile

 

 

 

Connect

 

 

 

 

 

 

 

 

 

 

Pilot

 

To 120V

 

 

 

 

Gas Line

 

N.O.SW

 

 

 

 

 

 

(Wall Switch

 

 

Incoming

 

 

 

Supplied)

 

 

 

TH

 

 

N.O.SW

 

Main

Control

 

 

 

TP

 

 

 

Gas

Valve

 

 

(Wall Switch

 

 

 

 

Not Supplied)

 

Supply

TPTH

 

 

 

 

 

Field Wire

 

 

 

* Remote

 

 

 

 

 

BLK

 

 

 

 

Control

 

Incoming

 

 

 

 

 

 

 

 

 

Wireway

 

WHT

120V AC

 

 

 

 

 

(Fuse Box

 

Blower

Variable Speed

 

GRN

or

 

Control

Electrical Rating:

 

 

Breaker)

* Use Extension Cord (Included With Kit)

 

Connectors

120v, 60Hz, 0.7A

GND

 

 

 

 

 

(Not Supplied)

 

For

 

 

.

.com

105706-01B

Page 24
Image 24
Desa VDVF36PN/PP, VDVF36STN/STP Replacement Parts Service Hints, Technical Service, Wiring Diagram, Parts Under Warranty