Desa VN2800BTA Trouble Shooting, ODS/PILOT and Burner, Cabinet, Air Passageways, Exterior

Models: VN2000BA VN2000BTA VN2800BTA

1 36
Download 36 pages 13.29 Kb
Page 24
Image 24

CLEANING

 

WARNING

AND

WARNING ICONG 001

Turn off heater and let cool before cleaning.

MAINTENANCE

 

 

 

 

 

 

 

WARNING ICONG 001

CAUTION

You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

 

TROUBLE-

 

 

WARNING ICONG 001WARNING

 

 

 

 

 

SHOOTING

 

 

 

 

 

 

 

Turn off and unplug heater and let cool before servicing. Only a

 

 

Note: All troubleshooting

qualified service person should service and repair heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

items are listed in order of

 

 

 

 

 

 

 

operation.

 

 

WARNING ICONG 001CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Never use a wire, needle, or similar object to clean ODS/pilot. This

 

 

 

 

can damage ODS/pilot unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

 

 

 

 

When ignitor button

1.

Ignitor electrode posi-

1.

Replace ignitor

 

 

is pressed, there is no

 

tioned wrong

 

 

 

 

 

 

spark at ODS/pilot

2.

Ignitor electrode broken

2.

Replace ignitor

 

 

 

3.

Ignitor electrode not con-

3.

Reconnect ignitor cable

 

 

 

 

nected to ignitor cable

 

 

 

 

 

 

 

4.

Ignitor cable pinched or

4.

Free ignitor cable if

 

 

 

 

wet

 

pinched by any metal or

 

 

 

 

 

 

tubing. Keep ignitor cable

 

 

 

 

 

 

dry

 

 

 

5.

Piezo ignitor nut is loose

5.

Tighten nut holding piezo

 

 

 

 

 

 

ignitor to heater cabinet.

 

 

 

 

 

 

Nut is located inside

 

 

 

 

 

 

heater cabinet at top

 

 

 

6.

Broken ignitor cable

6.

Replace ignitor cable

 

 

 

7.

Bad piezo ignitor

7.

Replace piezo ignitor

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

099570

Page 24
Image 24
Desa VN2800BTA, VN2000BA, VN2000BTA Trouble Shooting, ODS/PILOT and Burner, Cabinet, Air Passageways, Exterior

VN2000BA, VN2000BTA, VN2800BTA specifications

Desa VN2800BTA, VN2000BTA, and VN2000BA are three models of innovative heating solutions that embody advanced technology and comfort for residential and commercial use. These models are designed to provide efficient heating in various settings, ensuring warmth during the colder months while prioritizing user convenience and energy savings.

The VN2800BTA model stands out for its impressive heating capacity, making it suitable for larger spaces. It features a powerful output, capable of quickly warming a room while maintaining a consistent temperature. This model utilizes a user-friendly thermostat that allows for precise temperature control, ensuring optimal comfort without unnecessary energy consumption.

In contrast, the VN2000BTA and VN2000BA are designed for medium-sized areas, offering flexibility in different room configurations. Both models incorporate similar technological features, such as electronic ignition systems that enhance reliability and convenience. Owners can benefit from quick heat-up times, ensuring their environment remains cozy and inviting.

One of the defining characteristics of all three models is their commitment to safety. Each unit is equipped with built-in safety features, including oxygen depletion sensors and automatic shut-off mechanisms. These technologies provide peace of mind for users, allowing them to enjoy their heating systems without concern for safety hazards.

Additionally, all three models are designed with energy efficiency in mind. They utilize advanced combustion technologies that optimize fuel usage, resulting in reduced operational costs over time. This not only benefits the user financially but also contributes to lower environmental impact, aligning with modern sustainability goals.

In terms of aesthetics, the VN2800BTA, VN2000BTA, and VN2000BA models offer a sleek design that can blend seamlessly into any décor. The options for venting make installation versatile and adaptable to different home layouts, allowing for a customized heating solution.

Furthermore, the user experience is enhanced through easy-to-read displays and intuitive controls. This modern interface gives users a seamless interaction with their heating system, making adjustments a simple task.

Overall, Desa VN2800BTA, VN2000BTA, and VN2000BA models combine efficiency, safety, and style, making them an excellent choice for anyone looking to enhance their indoor comfort during chilly weather. With their robust features and user-focused design, these models set a high standard in the heating appliance market.