Desa (V)T32EP SERIES Continued, High Altitude Installation, Vertical Venting, Shown

Models: (V)T32EN SERIES (V)T32EP SERIES

1 40
Download 40 pages 26.37 Kb
Page 16
Image 16
Vertical Venting

Venting Installation

instructions

Continued

Note: Install restrictor into inner collar of fireplace as shown.

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

45° Elbow

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Note: Vertical (V1) + Vertical (V2) = 40' max.

Figure 23 - Vertical Venting

Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination

Shown)
Figure 24 - Vertical Venting

Configuration With No Horizontal Run

(Vertical Round High Wind Termination

Shown)

High Altitude Installation

Your DESAdirect-vent fireplace has been tested and approved for elevations from 0-2,000 feet (USA) and elevations from 0-4,500 feet (Canada).

When installing this fireplace at an elevation above 2,000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1,000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4,500 feet (in Canada), check with local authorities.

IMPORTANT: For horizontal installations above 2,000 feet, it is recommended that a 12" extension pipe be added before starter elbow (see Figure 25, page 17 ).

16

www.desatech.com

111987-01D

Page 16
Image 16
Desa (V)T32EP SERIES, (V)T32EN SERIES installation manual Continued, High Altitude Installation, Vertical Venting, Shown