![OPERATION](/images/new-backgrounds/100085/10008519x1.webp)
OPERATION
KNOW YOUR GENERATOR
Read this General Manual and Safety Rules before operation of your Generator. Compare the illustration in your parts manual with your generator to familiarize yourself with the location of various controls and adjustments. Save all manuals for future references.
|
|
| Fuel Cap (6) | Pilot |
|
| |
|
|
| Lamp (2) |
|
| ||
|
|
|
| AC Circuit |
|
| |
|
|
|
| Breakers (7) |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Muffler |
|
| Choke (11) |
|
|
|
|
| |
|
|
|
| Exhaust (9) |
| ||
|
|
|
|
|
|
| |
| Fuel Valve |
|
|
| |||
|
|
|
|
| |||
| Lever (10) |
|
|
|
| ||
| Engine |
| 12V DC |
| |||
|
| Outlet (3) |
| ||||
| On/Off |
|
| ||||
|
|
|
|
| |||
| Switch (1) |
|
| DC Circuit |
| ||
Receptacle (5) |
|
|
| ||||
|
| Breaker (7) |
|
Recoil
Starter (12)
Grounding
Screw (4)
Oil Fill (8)
1.Engine On/Off Switch - Enables and disables the ignition system.
2.Pilot Lamp - Indicates voltage is being provided by generator.
3.12V DC Outlet - Supplies voltage to 12V DC appliances. NOTE: This outlet is for operating 12V DC appliances only, DO NOT use this outlet to charge batteries.
4.Grounding Screw- This is the attachment point for a ground wire to an external earth ground.
5.Receptacle- 120V duplex supplies voltage to 120V appliances.
6.Fuel Cap - Fill the fuel tank with clean, fresh, unleaded gasoline with a pump octane rating of 87 or higher.
7.Circuit Breakers - Each receptacle has a circuit breaker to protect the gen- erator from overloading. If the circuit breaker trips, unplug all electrical loads from the generator. Let the circuit break- er cool down. Push circuit breaker button to reset.
8.Oil Fill - Fill the crankcase with SAE
9.Muffler Exhaust
10.Fuel Valve Lever - Opens and closes the connection between the fuel tank and the carburetor.
11.Choke- Opens and closes the choke valve in the carburetor.
12.Recoil Starter
A04669 | 10- ENG |