MAINTENANCE
CUSTOMER RESPONSIBILITIES TABLE
| Before | Every 25 | Every 50 | Every 100 |
| each | Hours of | Hours of | Hours of |
MAINTENANCE TASK | use | Every | Every | Every |
| Season | Season | Season | |
|
| |||
|
|
|
|
|
Check oil level | X | See Note 2 |
|
|
|
|
|
|
|
Change oil |
|
| See Note 1 |
|
|
|
|
|
|
Clean Air Filter Assembly |
| X |
|
|
Clean Fuel Valve Bowl |
|
|
| X |
Clean Fuel Filter |
|
|
| X |
Clean Fuel Tank Filter |
|
|
| X |
Clean Muffler Screen |
|
|
| X |
Check Spark Plug |
| X |
| See Note 3 |
Prepare Unit for Storage | Prepare unit for storage if it is to remain | |||
| idle for more than 30 days. |
| ||
|
|
|
|
|
Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in extremely dusty or dirty conditions.
Note 2: Check oil after 5 hours of operation.
Note 3: Every 100 hours of operation or once a year.
GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, operator must maintain the generator as instructed in this manual.
GENERATOR MAINTENANCE
Your generator should be kept clean and dry at all times. The generator should not be stored or operated in environments that include excessive moisture, dust or any corrosive vapors. If these substances are on the generator, clean with a cloth or soft bristle brush. Do not use a garden hose or anything with water pressure to clean the genera- tor. Water may enter the cooling air slots and could possibly damage the rotor, stator and the internal windings of the gen head.
ENGINE
To Check Oil
1.Shut down engine and place on a level surface.
2.Remove the oil filler cap/dipstick cover.