ASSEMBLY
Read this manual. Do not attempt to operate
equipment until you have read this Manual for Safety, Operation, and Maintenance Instructions.
NOTE: Left and right describes the location of a part with the operator facing the outlet panel.
REMOVE GENERATOR FROM CARTON
•Open carton from top.
•Locate and remove the handle kit.
•Assemble the handle to the top of the generator using the screwdriver and screws supplied. Save the screwdriver and spark plug wrench for future use.
•Carefully lift generator from carton.
GROUNDING THE GENERATOR
A grounding screw is supplied on the generator for use when required by local electrical ordinances. Refer to article 250 of the National Electrical Code to clarify any needed grounding information. Your local electric company or a certified electrician should be able to help you with this information.
EXTENSION CORDS
When using an appliance or tool at a considerable distance from the generator, a
Extension Cord Wire Gauge Chart
Cord | Wire | Amperage |
Length | Gauge | |
| Size |
|
0 to | 14 ga. | Up to 10 |
100 ft. |
| amp draw |
An extension cord that is hot to the
touch is overloaded. Repair or replace damaged extension cords immediately.
DO NOT connect this generator to the main electrical supply coming into a house.
9- ENG | A04669 |