ASSEMBLY

ASSEMBLY

Read this manual. Do not attempt to operate

equipment until you have read this Manual for Safety, Operation, and Maintenance Instructions.

NOTE: Left and right describes the location of a part with the operator facing the outlet panel.

REMOVE GENERATOR FROM CARTON

Open carton from top.

Locate and remove the handle kit.

Assemble the handle to the top of the generator using the screwdriver and screws supplied. Save the screwdriver and spark plug wrench for future use.

Carefully lift generator from carton.

GROUNDING THE GENERATOR

A grounding screw is supplied on the generator for use when required by local electrical ordinances. Refer to article 250 of the National Electrical Code to clarify any needed grounding information. Your local electric company or a certified electrician should be able to help you with this information.

EXTENSION CORDS

When using an appliance or tool at a considerable distance from the generator, a 3-wire extension cord that has a 3-blade grounding plug and a

3-slot receptacle that accepts the tool's plug MUST be used in order to reduce the risk of electrical shock. A cord of adequate size must be used. Using the following chart to determine the minimum wire size required.

Extension Cord Wire Gauge Chart

Cord

Wire

Amperage

Length

Gauge

 

Size

 

0 to

14 ga.

Up to 10

100 ft.

 

amp draw

An extension cord that is hot to the

touch is overloaded. Repair or replace damaged extension cords immediately.

DO NOT connect this generator to the main electrical supply coming into a house.