DeVillbiss Air Power Company GM1000, A04669 Troubleshooting Guide, Problem, Cause, Correction

Models: A04669 GM1000

1 72
Download 72 pages 16.39 Kb
Page 22
Image 22
TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

PROBLEM

 

CAUSE

 

CORRECTION

Engine will not

1.

Low on fuel or oil.

1.

Add fuel or oil.

start

2.

Engine On/Off switch in

2.

Place in the ON position

 

 

 

Off position.

 

 

 

3.

Faulty spark plug.

3.

Replace spark plug.

 

4.

Choke in wrong position.

4.

Adjust choke accordingly.

 

5.

Fuel valve lever in closed

5.

Open fuel valve lever.

 

 

position

 

 

 

6.

Unit loaded during

6.

Remove load from unit.

 

 

start-up.

 

 

 

7.

Spark plug wire loose.

7.

Attach wire to spark plug.

 

8.

Fuel line clogged.

8.

Clean fuel line and fuel filter.

 

9.

Faulty ignition system.

9.

Consult a Service Center.

 

 

 

 

 

No electrical

1.

Faulty receptacle.

1.

Have Service Center replace.

output

2.

Circuit breaker kicked

 

 

 

2.

Depress and reset.

 

 

out.

 

 

 

3.

Defective capacitor.

3.

Have Service Center replace

 

 

 

 

capacitor.

 

4.

Faulty power cord.

4.

Repair or replace cord.

 

 

 

 

 

Repeated

1.

Overload

1.

Reduce load.

circuit breaker

2.

Faulty cords or

2.

Check for damaged, bare, or

tripping

 

equipment

 

frayed wires on equipment.

 

 

 

 

 

 

 

Replace.

 

 

 

 

 

Generator

1.

Generator overloaded.

1.

Reduce load.

overheating

2.

Insufficient ventilation.

2.

Move to adequate supply of

 

 

 

 

 

fresh air.

 

 

 

 

 