TROUBLESHOOTING GUIDE

Stop using the Tool immediately if any of the following occur.

Serious personal injury could occur.

Warranty repairs or replacements must be performed by a DeVilbiss Air Power

Authorized Service Center Only.

PROBLEM

CAUSE

 

SOLUTION

 

 

 

Air leaking at trigger valve

Seals in trigger valve housing

Seals must be replaced &

area.

are damaged.

operation of Contact trip must

 

 

be checked. On the NBSNC2x4

 

 

contact *AWSC for correct part.

 

 

All other nailers purchase

 

 

Trigger Repair Kit.

 

 

 

Air leaking through the

Broken /worn head valve spring.

Spring needs to be replaced. On

exhaust deflector.

Broken /worn head valve seals.

the NBSNC2x4 contact *AWSC

 

 

for correct part. All other nailers

 

 

purchase Top Repair Kit.

 

 

Seals

must be replaced.

 

 

Purchase Top Repair Kit on all

 

 

nailers.

 

 

 

 

Tool fails to drive fastener.

Worn or damaged driver guide.

Driver guide needs to be replaced.

 

 

Purchase Driver Blade Kit

 

Damaged feed pawl.

Replace feed pawl. Contact a

 

 

*AWSC

 

 

Worn feed pawl spring.

Replace feed pawl spring. Con-

 

 

tact a *AWSC

 

Damaged feed pawl pin.

Replace feed pawl pin. Contact a

 

 

*AWSC

 

 

Inadequate air flow or pressure

Verify air flow or pressure to tool.

 

to Tool.

 

 

 

Worn seal on piston or lack of

Replace

or lubricate seal.

 

lubrication.

Purchase Bottom Repair Kit

 

Damaged seal on trigger valve.

Replace seal. Purchase Trigger

 

 

Repair Kit

 

Air leaks.

Screws and fittings need to be

 

 

tightened.

 

Cap seal leaking.

Replace seal. Purchase Top Re-

 

 

pair Kit

 

 

 

 

Tool runs slow or has loss

Tool not lubricated sufficiently.

Tools needs to be lubricated.

of power.

Inadequate air flow or pressure

Verify air flow or pressure to tool.

 

 

to tool.

 

 

 

Worn seal on piston.

Replace seal. Purchase Bottom

 

 

Repair Kit

 

Broken spring in cylinder cap.

Spring needs to be replaced.On

 

 

the NBSNC2x4 contact *AWSC

 

 

for correct part. All other nailers

 

 

purchase Top Repair Kit.

 

Worn head valve seals.

Replace seals. Contact a *AWSC

 

 

 

 

PAGE 15