POWER CONNECTIONS
A separate electrical circuit should be used for your machines:
FOR SINGLE PHASE UNITS (EXCEPT THE FIVE HORSEPOWER): This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse.
FOR FIVE HORSEPOWER, SINGLE PHASE UNITS: The circuit should not be less than #10 wire and should be protected with a 40 Amp time lag fuse.
FOR PERMANENTLY CONNECTED MACHINES: See No. 3 in “GROUNDING INSTRUCTIONS”.
If an extension cord is used, use only
Do not expose the machine to rain or operate the machine in damp locations.
MOTOR SPECIFICATIONS
All Unisaw motors are rated for 60 HZ alternating current, but voltage and HP varies according to model:
Model: | Specifications: |
3HP, 230V single phase motor | |
5HP, 230V single phase motor | |
5 HP, |
Before connecting the machine to the power source, make sure that the switch is in the “OFF” position.
GROUNDING INSTRUCTIONS
1. All grounded, cord-connected machines:
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This machine is equipped with an electric cord having an
Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.
Improper connection of the
Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the machine is properly grounded.
Use only
2.Grounded,
If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A, the machine will have a grounding plug that looks like the plug illustrated in Fig. A. Make sure the machine is connected to an outlet having the same configuration as the plug. No adapter is available or should be used with this machine. If the machine must be
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.
In all cases, make certain that the receptacle in question is properly grounded. If you are not sure, have a qualified electrician check the receptacle.
CURRENT | GROUNDED OUTLET BOX |
| |
CARRYING |
|
PRONGS |
|
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
6