DeWalt released, Factory Reset, Installation, Corinex AV200 Powerline Ethernet Wall Mount

Models: AV200

1 50
Download 50 pages 47.74 Kb
Page 11
Image 11
released.

Installation

1.Identify which is the AP adapter in an existing PLC network. The AP adapter always shows its AP indicator ON in green. The other adapters are EPs and their AP indicators will be OFF;

2.Next, press “SYNC/RST” button for around two seconds on the AP adapter until its AP indicator starts blinking. This opens a configuration period of 30 seconds;

3.During this configuration period, press the “SYNC/RST” button on the new EP adapter(s) until their AP indicator starts blinking, then release the button. Exchanging of Network ID and Encryption Key between AP and new EPs is done automatically. All the new adapters and the AP device finish their configuration process successfully when their AP indicator flashes three times during 0.5 seconds. All adapters then return to normal operation mode belonging to the same powerline network.

Note:

1.The adapters during the configuration process shall be within close proximity such that they are able to communicate with each other without a network identifier and an encryption key.

2.When adding adapters to the network, the button of the second adapter should be pressed only after the button of the first adapter has been

released.

9

 

2.4.2.2 Factory Reset

Perform the following steps to do a factory reset:

1.Press the adapter’s “SYNC/ RST” button for at least ten seconds (its lower LED will start blinking in green once the button has been pressed for two seconds, and will keep blinking for about eight seconds). When the VPI LED switches OFF, release the button.

2.After five seconds, the VPI LED will switch ON again.

3.At this time, the adapter resets its configuration to the factory default settings and automatically restarts

The significant factory settings in the AV200 Wall Mount are presented below:

Default IP is 10.10.1.69

Default configuration password is “paterna”

Default factory reset password is “betera”

Default network ID is the public network ID

Default Encryption Key is none.

Corinex AV200 Powerline Ethernet Wall Mount

Page 11