5 Power, Thermal, Acoustic
5.1 Power Supplies
The
For the 8 and 12 HDD configuration 750W hot plug redundant PSUs, Dell offers two options:
∙n+0,
∙n+1,
In order to supply power to the processors, standard Voltage Regulator Down (VRD) modules conform to VRD (Performance 2005 FMB) specification. This approach reduces the board layout complexity while offering design modularity. As processor speeds increase, a newer VRD can be used to accommodate the power increase with no need to
There are 2 separate power supply connectors on the
The 2x12 ATX connector provides 3.3V, 5V, 12V, and 12V standby to the system. 3.3V standby is provided to the system through a buck converter from 12V standby.
| Pin |
|
| SIGNAL |
|
| Pin |
|
| SIGNAL |
|
| 1 |
|
| P5V |
|
| 13 |
|
| P12V_AUX |
|
| 2 |
|
| P5V |
|
| 14 |
|
| P3V3 |
|
| 3 |
|
| P3V3 |
|
| 15 |
|
| P3V3 |
|
| 4 |
|
| SINGLE_PS_PRE |
|
| 16 |
|
| PS_ENABLE_CPLD_ |
|
|
|
| S_N |
|
|
|
| N |
| ||
|
|
|
|
|
|
|
|
|
| ||
| 5 |
|
| PS_PWROK |
|
| 17 |
|
| GND |
|
| 6 |
|
| GND |
|
| 18 |
|
| GND |
|
| 7 |
|
| GND |
|
| 19 |
|
| GND |
|
| 8 |
|
| GND |
|
| 20 |
|
| GND |
|
| 9 |
|
| GND |
|
| 21 |
|
| P12VC |
|
| 10 |
|
| P12VC |
|
| 22 |
|
| P12VC |
|
| 11 |
|
| P12VC |
|
| 23 |
|
| P12VC |
|
| 12 |
|
| P12VC |
|
| 24 |
|
| P12VC |
|
Figure 30. Power Supply Connector (24 pins)