Dell
Table 25. Raid Configurations for the PowerEdge R510-8
|
|
|
|
|
|
|
|
|
|
| No Mixed |
| |||
|
|
|
|
|
|
|
|
|
|
| HDD |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| (Must be all |
| |||
|
|
|
|
|
|
|
|
|
|
| 2.5" or 3.5" |
| |||
| PowerEdge |
|
| ||||||||||||
|
|
| HDDs) |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Min |
|
| Max |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Type |
| # |
|
| Name |
| Description |
|
| HDD |
|
| HDD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NCZ |
|
|
|
|
|
|
|
|
|
| No |
|
|
|
| (recommended |
| No Hard Drive (controller required, PERC S300, SAS 6/iR, |
|
|
|
|
|
| |
| HDD |
| 16 |
|
| for hidden) |
| PERC H200, PERC 6/i, PERC H700) | 0 |
| 0 |
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||||
| SW |
| 17A |
| ASSR0 |
| RAID0 for 2 HDDs (PERC S300) | 2 |
| 2 |
| ||||
| RAID |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 17B |
| ASSR0 |
| RAID0 for 3 and above HDDs (PERC S300) | 3 |
| 8 |
| |||||
| (Add- |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| in |
| 18 |
|
| ASSR1 |
| RAID1 (PERC S300) | 2 |
| 2 |
| |||
| card) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 19 |
|
| ASSR10 |
| RAID10 (PERC S300) | 4 |
| 8 |
| ||||
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 20 |
|
| ASSR5 |
| RAID5 (PERC S300) | 3 |
| 8 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (Add- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| in |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| card) |
| 21 |
|
| ASS |
| No RAID (SAS 6/iR, PERC H200) | 1 |
| 8 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| RAID |
| 22 |
|
| ASSR0 |
| RAID0 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700) | 2 |
| 8 |
| |||
| (Add- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 23 |
|
| ASSR1 |
| RAID1 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700) | 2 |
| 2 |
| ||||
| in |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| card) |
| 24 |
|
| ASSR10 |
| RAID10 (PERC H200, PERC 6/i, PERC H700) | 4 |
| 8 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 25 |
|
| ASSR5 |
| RAID5 (PERC 6/i, PERC H700) | 3 |
| 8 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 26 |
|
| ASSR6 |
| RAID6 (PERC 6/i, PERC H700) | 4 |
| 8 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 27 |
|
| ASSR50 |
| RAID50 (PERC 6/i, PERC H700) | 6 |
| 8 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 28 |
|
| ASSR60 |
| RAID60 (PERC 6/i, PERC H700) | 8 |
| 8 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 29 |
|
| ASSR1/R1 |
| RAID1+RAID1 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700) | 2 + 2 |
| 2 + 2 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 30 |
|
| ASSR1/R5 |
| RAID1 + RAID5 (PERC 6/i, PERC H700) | 2 + 3 |
| 2 + 6 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 31 |
|
| ASSR5/R10 |
| RAID5 + RAID10 (PERC 6/i, PERC H700) | 4 + 4 |
| 4 + 4 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PowerEdge R510 Technical Guide | 58 |