Dell

11.3 RAID Configurations

Table 24. Raid Configurations for the PowerEdge R510-4

 

 

 

 

 

 

 

 

 

No Mixed

 

 

 

 

 

 

 

 

 

 

HDD

 

 

 

 

 

 

 

 

 

 

 

(3.5" HDD

 

 

PowerEdge R510-4 Factory Configuration

ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

 

Max

 

 

Type

 

#

 

 

Name

 

Description

HDD

 

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NCZCBL

 

 

 

 

 

 

 

 

No

 

 

 

 

(recommended

 

 

 

 

 

 

 

 

HDD

 

0

 

 

for hidden)

 

No controller/No Hard Drive

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID

 

1

 

 

MSTCBL

 

No RAID (ICH)

1

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

 

2A

 

MSTR0CBL

 

RAID0 for 2 HDDs (PERC S100)

2

 

 

2

 

 

RAID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2B

 

MSTR0CBL

 

RAID0 for 3 and above HDDs (PERC S100)

3

 

 

4

 

 

(ICH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

MSTR1CBL

 

RAID1 (PERC S100)

2

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

MSTR10CBL

 

RAID10 (PERC S100)

4

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

MSTR5CBL

 

RAID5 (PERC S100)

3

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

 

6A

 

ASSR0CBL

 

RAID0 for 2 HDDs (PERC S300)

2

 

 

2

 

 

RAID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6B

 

ASSR0CBL

 

RAID0 for 3 and above HDDs (PERC S300)

3

 

 

4

 

 

(Add-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

card)

 

7

 

 

ASSR1CBL

 

RAID1 (PERC S300)

2

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

ASSR10CBL

 

RAID10 (PERC S300)

4

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

ASSR5CBL

 

RAID5 (PERC S300)

3

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID

 

 

 

 

 

 

 

 

 

 

 

 

 

(Add-in

 

 

 

 

 

 

 

 

 

 

 

 

 

card)

 

10

 

 

ASSCBL

 

No RAID (SAS 6/iR, PERC H200)

1

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

ASSR0CBL

 

RAID0 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700)

2

 

 

4

 

 

RAID

 

 

 

 

 

 

 

 

(Add-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

ASSR1CBL

 

RAID1 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700)

2

 

 

2

 

 

card)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

ASSR10CBL

 

RAID10 (PERC H200, PERC 6/i, PERC H700)

4

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

ASSR5CBL

 

RAID5 (PERC 6/i, PERC H700)

3

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 +

 

 

2 +

 

 

 

 

15

 

 

ASSR1/R1CBL

 

RAID1+RAID1 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700)

2

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PowerEdge R510 Technical Guide