11.3 RAID Configurations
Table 24. Raid Configurations for the PowerEdge R510-4
|
|
|
|
|
|
|
|
| No Mixed |
| |||
|
|
|
|
|
|
|
|
| HDD |
|
| ||
|
|
|
|
|
|
|
|
| (3.5" HDD |
| |||
| PowerEdge | ONLY) |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Min |
|
| Max |
|
| Type |
| # |
|
| Name |
| Description | HDD |
|
| HDD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NCZCBL |
|
|
|
|
|
|
|
| No |
|
|
|
| (recommended |
|
|
|
|
|
|
|
| HDD |
| 0 |
|
| for hidden) |
| No controller/No Hard Drive | 0 |
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
|
|
|
|
|
|
|
|
|
|
|
| RAID |
| 1 |
|
| MSTCBL |
| No RAID (ICH) | 1 |
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| SW |
| 2A |
| MSTR0CBL |
| RAID0 for 2 HDDs (PERC S100) | 2 |
|
| 2 |
| |
| RAID |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2B |
| MSTR0CBL |
| RAID0 for 3 and above HDDs (PERC S100) | 3 |
|
| 4 |
| ||
| (ICH) |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 3 |
|
| MSTR1CBL |
| RAID1 (PERC S100) | 2 |
|
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 |
|
| MSTR10CBL |
| RAID10 (PERC S100) | 4 |
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 |
|
| MSTR5CBL |
| RAID5 (PERC S100) | 3 |
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| SW |
| 6A |
| ASSR0CBL |
| RAID0 for 2 HDDs (PERC S300) | 2 |
|
| 2 |
| |
| RAID |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6B |
| ASSR0CBL |
| RAID0 for 3 and above HDDs (PERC S300) | 3 |
|
| 4 |
| ||
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| card) |
| 7 |
|
| ASSR1CBL |
| RAID1 (PERC S300) | 2 |
|
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 |
|
| ASSR10CBL |
| RAID10 (PERC S300) | 4 |
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 9 |
|
| ASSR5CBL |
| RAID5 (PERC S300) | 3 |
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
|
|
|
|
|
|
|
|
|
|
|
| RAID |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| card) |
| 10 |
|
| ASSCBL |
| No RAID (SAS 6/iR, PERC H200) | 1 |
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 11 |
|
| ASSR0CBL |
| RAID0 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700) | 2 |
|
| 4 |
| |
| RAID |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 12 |
|
| ASSR1CBL |
| RAID1 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700) | 2 |
|
| 2 |
| |
| card) |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 13 |
|
| ASSR10CBL |
| RAID10 (PERC H200, PERC 6/i, PERC H700) | 4 |
|
| 4 |
| |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 14 |
|
| ASSR5CBL |
| RAID5 (PERC 6/i, PERC H700) | 3 |
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 + |
|
| 2 + |
|
|
|
| 15 |
|
| ASSR1/R1CBL |
| RAID1+RAID1 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700) | 2 |
|
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PowerEdge R510 Technical Guide | 57 |