Dimension One Spas 2000 Model manual A Circuit

Models: 2000 Model

1 50
Download 50 pages 62.5 Kb
Page 18
Image 18
30 A Circuit

2000 Owner’s Manual

16

1)Remove the screws holding the equipment access panel to the front of the spa cabinet and set the panel aside.

2)Loosen the four screws located on the front of the black equipment control can and remove the door from the control can to allow access to the four wire connection terminal block.

3)Attach 1” rigid non-metallic conduit to the conduit nipple located in the pedestal base on the side of the spa and run required conductors through the conduit to the equipment can.

4)Connect the four wires to the equipment system terminal block (TB1) as indicated on the wiring diagram in the back of this manual.

5)Configure jumpers 1 and 2 on the upper right corner of the PC Board to match the circuit size being used for the spa (see Electrical Requirements Chart on previous page for proper wire size). See the chart below for the correct settings.

1

2

1

2

 

JMP1

 

JMP1

 

JMP2

 

JMP2

30 A Circuit

40 A Circuit

1

2

1

2

 

JMP1

 

JMP1

 

JMP2

 

JMP2

15 A Circuit

50 A Circuit

6)Replace the door on the control can and re-tighten the securing screws.

7)Electrical hook-up is now complete. Do not replace the equipment access panel yet.

If you have an Aurora HP, Interlude, Arena or Triad or please read below for Initial Start-up Information. If you have a Chairman II, Diplomat, Chairman, Californian, Nautilus, Aurora II or Triad II, please turn to page 27 for Initial Start-up information.