2000 Owner’s Manual

17

INITIAL START-UP FOR THE AURORA HP , INTERLUDE, ARENA AND TRIAD

1)Before filling your spa, install the hose bib that is included in the owner’s manual packet located in the equipment compartment. Screw the hose bib onto the male fitting located at the bottom of the spa on the pedestal, to the lower left of the equipment compartment. Close the valve on the side of the hose bib and screw the cap onto the end of the hose bib.

2)Check the pump unions to be sure that they are tight to prevent the possibility of leakage in the equipment compartment. Also, open the bleeder valve located next to the sidewall of the skimmer area to allow air to escape from the pump(s).

3)Fill your spa with water to a level of one to two inches above the bottom of the tile line.

4)Remove the two shipping bolts located on the front of the pump mount and ensure that the gate valves on the pump are in the open position (handles fully extended).

5)Turn on the circuit breaker. Dashed lines will appear for 30 seconds on the LCD followed by the current water temperature flashing. Press the UP or DOWN pads to set your desired spa temperature. If your spa is equipped with the CrystalZone Water Management System and there is a call for heat, the circulation pump will then activate and turn on the heater. If CrystalZone is not installed, and there is a call for heat, the low speed pump will come on with the heater. One minute after start-up, the internal time clock is auto- matically set to initiate the first filtration cycle. The system factory default is two, one hour cycles. Let the system run for 30 to 45 sec- onds to prime the pump(s). If there is no jet action, then the water level is too low, the gate valves are closed or there is air trapped in the plumbing lines. To eliminate the trapped air, turn the pump(s) on and off several times to force the trapped air through the pump(s). If there is still no jet action, and the bleeder valve has been open for some time, turn off the pump(s) and loosen the top pump union slightly to let any trapped air escape. Re-tighten the pump union