Dimplex DF3215 manual Maintenance, Light Bulb Replacement, Lower Light Bulb Requirements

Models: DF3215

1 20
Download 20 pages 29.58 Kb
Page 15
Image 15
MAINTENANCE

MAINTENANCE

WARNING

Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons.

LIGHT BULB REPLACEMENT

Allow at least 5 minutes for light bulbs to cool before touching bulbs to avoid accidental burning of skin.

Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log ember bed exterior disappears. There are four bulbs under the log set, which generate the flames and embers, and two bulbs above the log that illuminate the log exterior.

LOWER LIGHT BULB REQUIREMENTS

Quantity of 4 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 watt rating. Example: GE 60BC or Philips 60 CTC.

DO NOT EXCEED 60 WATTS PER BULB

HELPFUL HINTS

It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace light bulbs. Care must be taken when removing the logset as the logset contains LED’s and wires.

To access the lower light bulb area:

1.Open the bi-fold doors.

2.Pull the front edge of the plastic ember bed or plastic grate up and forward until the rear tab releases from the ledge located at the bottom of the mirror.

IMPORTANT

 

 

ONLY handle the logset by the emberbed.

 

 

NOTE

 

 

Logset fits tightly into firebox, some force may

Light Bulb

 

be necessary to remove.

 

3.

Set logset in front of firebox.

LED Wire

 

4.

Disconnect the logset LED wire harness

Harness

 

 

from unit.

 

 

5.

Lift the left side of the flame rod out of

 

 

 

the mounting bracket.

 

 

6.

Examine the bulbs to determine which

 

 

 

bulbs require replacement.

 

 

7.

Unscrew bulbs counter clockwise.

 

 

8.

Insert new bulbs.

 

 

9.

Install the left side of the flame rod to

 

 

 

the mounting bracket.

Logset

 

10. Reconnect the logset LED wire harness.

FIGURE 7

 

11.Replace the logset by inserting the front of

 

 

 

the emberbed under the front edge of the

 

 

 

fireplace and push down on the rear edge of

 

 

 

the emberbed until it snaps into place

 

 

 

(FIGURE 8).

 

 

NOTE

 

 

Ensure the logset is installed tightly under the back ledge

 

to prevent light leakage.

FIGURE 8

 

12. Close the bi-fold doors.

13

Page 15
Image 15
Dimplex DF3215 Maintenance, Light Bulb Replacement, Lower Light Bulb Requirements, To access the lower light bulb area