OPERATION

To start an engine with a weak battery

WARNING!

Lead-acid batteries generate explosive gases. Keep sparks, flame and smoking materials away from batteries. Always wear eye protection when around batteries.

If your battery is too weak to start the engine, it should be recharged. (See “Battery” in the Maintenance Section.)

If “jumper cables” are used for emergency starting, follow this procedure:

IMPORTANT INFORMATION

Your mower is equipped with a 12-volt negative grounded system. The other vehicle must also be a 12-volt negative grounded system. Do not use your mower to start other vehicles.

8011-642

Jumper cable connection

To attach jumper cables

Connect each end of the RED cable to the POSITIVE (+) terminal on each battery, taking care not to short against chassis.

Connect one end of the BLACK cable to the NEGATIVE (-) terminal of the fully charged battery.

Connect the other end of the BLACK cable to a good CHASSIS GROUND on the mower with the discharged battery, away from the fuel tank and battery.

To remove cables, reverse order

Remove BLACK cable first from chassis and then from the fully charged battery.

Remove RED cable last from both batteries.

English-31

Page 31
Image 31
Dixon 27 KOH/968999588 To start an engine with a weak battery, To attach jumper cables, To remove cables, reverse order