DP600 Front Panel
Dolby® DP600 Program Optimizer Manual 7
LEDs2,3,and4indicatethestatusoftheotherthreephysicaldisks.Thesedisksare
configuredasseparatedrivesanddonothaveRAIDbackupcapability.Ifanyofthese
drivesfail,thefaileddrivesmustbereplaced,andanyworkordersinprogressduringthe
failuremustberestarted.
IfoneofthedriveLEDsturnsred,refertoTable 1 1todeterminewhichphysicaldrive
failed.Typic ally,theDP600automaticallyrebuildstheRAIDarraywhenoneoftheRAID
driveshasaproblemorisreplaced(withthepoweron).DuringtheRAIDrebuildprocess,
LED1blinksinredinhalfsecondintervals.Whentherebuildprocessiscomplete,LED1
stopsblinking.
Insomeinstances,youmustinitiatetherebuildprocessmanually(asdescribedin
RebuildingaDriveonpage49).Forexample,ifyou replaceanonRAIDdrive.
IfyoureplacebothRAIDdrives,youalsoneedtoreinstalltheDP600software.Insucha
case,followtheinstructionsforacleaninstallationinUpgrading/InstallingtheDP600
Softwareonpage55.Whenyoureinst allthesoftware,thesystemautomatically
synchronizesthetwoRAIDdrives,recreatingtheoriginalmirroredRAIDarray(manual
rebuildnotrequired).
Forinstructionsonreplacingadrive,seeReplacingaDriveonpage44.
Table 1-1 Local Storage LED Conditions

1.5.6 USB 2.0 Port

ThefrontpanelUSB2.0portisprovidedforlicenseloadingfromaUSBflashdriveor
toconnecttheprovidedUSBkeyboard.
Front-Panel LED Condition Failed Physical Drive
1Solidred 1
1Blinksinredin
twosecondintervals
2
1Blinksinredin
halfsecondintervals
RebuildingRAID
2Solidred 3
3Solidred 4
4Solidred 5