DP600 Front Panel
Dolby® DP600 Program Optimizer Manual 7
LEDs2,3,and4indicatethestatusoftheotherthreephysicaldisks.Thesedisksare
configuredasseparatedrivesanddonothaveRAIDbackupcapability.Ifanyofthese
drivesfail,thefaileddrivesmustbereplaced,andanyworkordersinprogressduringthe
failuremustberestarted.
IfoneofthedriveLEDsturnsred,refertoTable 1 ‐1todeterminewhichphysicaldrive
failed.Typic ally,theDP600automaticallyrebuildstheRAIDarraywhenoneoftheRAID
driveshasaproblemorisreplaced(withthepoweron).DuringtheRAIDrebuildprocess,
LED1blinksinredinhalf‐secondintervals.Whentherebuildprocessiscomplete,LED1
stopsblinking.
Insomeinstances,youmustinitiatetherebuildprocessmanually(asdescribedin
RebuildingaDriveonpage49).Forexample,ifyou replaceanon‐RAIDdrive.
IfyoureplacebothRAIDdrives,youalsoneedtoreinstalltheDP600software.Insucha
case,followtheinstructionsforacleaninstallationinUpgrading/InstallingtheDP600
Softwareonpage55.Whenyoureinst allthesoftware,thesystemautomatically
synchronizesthetwoRAIDdrives,recreatingtheoriginalmirroredRAIDarray(manual
rebuildnotrequired).
Forinstructionsonreplacingadrive,seeReplacingaDriveonpage44.
Table 1-1 Local Storage LED Conditions
1.5.6 USB 2.0 Port
ThefrontpanelUSB2.0portisprovidedforlicenseloadingfromaUSBflashdriveor
toconnecttheprovidedUSBkeyboard.
Front-Panel LED Condition Failed Physical Drive
1Solidred 1
1Blinksinredin
two‐secondintervals
2
1Blinksinredin
half‐secondintervals
RebuildingRAID
2Solidred 3
3Solidred 4
4Solidred 5