VigorSwitch P2260 User’s Guide 97
Parameter description:
Port Number: Choose the port that you would like this function to work on
it. Valid range of the port is 1~26.
Rate: Set up the limit of Ingress bandwidth for the port you choose.
Incoming traffic will be discarded if the rate exceeds the
value you set up in Data Rate field. Pause frames are also
generated if flow control is enabled. The format of the
packet limits to unicast, broadcast and multicast. Valid value
of Port 1~24 ranges from 66~102400, and Port 25~26 ranges
from 66~1024000 with the minimum unit of 1. Default value
of Port 1~24 is 102400 and Port 25~26 is 1024000.
2
2.
.1
17
7.
.2
2
E
Eg
gr
re
es
ss
s
Function name:
Ingress Bandwidth Control/Egress Bandwidth Control
Function description:
Egress Bandwidth Setting function is used to set up the limit of Egress bandwidth for each
port.