Troubleshooting

Related messages (continued)

Message

CHECK THE AIR FLOW

Description

The internal temperature is rising.

Please turn the power off, and allow the projector to cool down at least 20 minutes. After having confi rmed the following items, please turn the power ON again.

Is there blockage of the air passage aperture?

Is the air fi lter dirty?

Does the peripheral temperature exceed 35°C?

If the same indication is displayed after the remedy, please set FAN SPEED of the SERVICE item in the OPTION menu to HIGH.

REMINDER

*** HRS PASSED AFTER THE

LAST FILTER CHECK.

FILTER MAINTENANCE IS ESSENTIAL TO REMOVE WARNING MESSAGE, RESET FILTER TIMER.

SEE MANUAL FURTHER INFO.

A note of precaution when cleaning the air filter.

Please immediately turn the power off, and clean or change the air fi lter referring to the “Air Filter” section of this manual. After you have cleaned or changed the air fi lter, please be sure to reset the fi lter timer( 40)

NOTE • A lamp has a fi nite product life. Lamps are characterized by the fact that, after long hours of usage, a lamp will no longer light up, or the lamp will break or burst, etc. This projector is equipped with an automatic shut-down function, such that the power will automatically be turned off when lamp usage time has reached 2000 hours. Please be aware, however, that among lamp types, there are major differences in product lifetimes; a lamp may thus fail to light even prior to the functioning of the automatic shut-down function of this projector.

43

Page 45
Image 45
Dukane 8914 user manual Related messages, Internal temperature is rising