DIGITAL SYSTEM AMPLIFIER

not affected by VLD. Power amplifier channels behave as described in chapter 2.7. The use of VLD considerably expands the adaptability of a power amplifier. Table 2.4 lists some application examples of VLD.

 

2 Ω

 

4 Ω

8 Ω

125 W

 

 

 

2 Ω Mode DSA 8x05

 

 

 

 

 

 

 

2 Ω Mode DSA 8x05

4 Ω Mode DSA 8x05

250 W

 

or

 

 

 

 

2 Ω Mode DSA 8410

 

 

 

 

500 W

2 Ω Mode DSA 8x05

4 Ω Mode DSA 8x05 or

4 Ω Mode DSA 8410 or

2

Ω Mode DSA 8410

Bridge 2 Ω DSA 8x05

 

 

 

 

 

 

1000 W

2 Ω Mode DSA 8410

4 Ω Mode DSA 8410 or

Bridge 4 Ω DSA 8x05 or

Bridge 2 Ω DSA 8x05

Bridge 2 Ω DSA 8410

 

 

 

 

 

 

2000 W

 

Bridge 2 Ω DSA 8410

Bridge 4 Ω DSA 8410

 

 

 

 

 

Table 2.3: Maximum Output Power (VLD deactivated)

 

2 Ω

4 Ω

8 Ω

125 W

VLD, all types

VLD, all types

2 Ω Mode DSA 8x05 or

VLD DSA 8410

 

 

 

 

 

 

 

250 W

VLD, all types

2 Ω Mode DSA 8x05 or

4 Ω Mode DSA 8x05 or

VLD DSA 8410

2 Ω Mode DSA 8410

 

 

 

 

 

 

 

VLD DSA 8410 or

4 Ω Mode DSA 8x05 or

VLD DSA 8x05 or

500 W

4 Ω Mode DSA 8410 or

2 Ω Mode DSA 8x05

2 Ω Mode DSA 8410

 

Bridge 2 Ω DSA 8x05

 

 

 

 

 

 

 

 

2 Ω Mode DSA 8410

4 Ω Mode DSA 8410 or

VLD DSA 8410 or

1000 W

Bridge 4 Ω DSA 8x05 or

Bridge 2 Ω DSA 8x05

 

 

Bridge 2 Ω DSA 8410

 

 

 

 

 

 

 

2000 W

 

Bridge 2 Ω DSA 8410

Bridge 4 Ω DSA 8410

 

 

 

 

Table 2.4: Maximum Output Power (VLD activated)

2.9 Power on delay

The ON DELAY switch on the amplifier rear panel allows selection of the power on delay time. Following table shows possible switch settings and corresponding delay times in seconds.

ON DELAY

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delay time

0

0.15

0.3

0.45

0.6

0.75

0.9

1.05

1.2

1.35

1.5

1.65

1.8

1.95

2.1

2.25

(in s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION:

The setting of ON DELAY is ignored if a Remote Control Module is assembled.

12 Owner‘s Manual

Page 12
Image 12
Dynacord DSA 8410, DSA 8805, DSA 8405 owner manual Power on delay, Maximum Output Power VLD deactivated