Eiki EIP-1000T owner manual Resetting the Lamp Timer

Models: EIP-1000T

1 64
Download 64 pages 4.47 Kb
Page 55
Image 55

Regarding the Lamp (Continued)

4 Remove the lamp unit.

Handle

• Loosen the securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it.

5 Insert the new lamp unit.

Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws.

6 Replace the lamp unit cover.

Align the tab on the lamp unit cover (1)and place it while pressing the tab (2) to close it. Then tighten the user ser- vice screw to secure the lamp unit cover.

Info

If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is con- nected to the projector.

Securing screws

2

1

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

Info

Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or ex- plode.

1Connect the power cord.

Plug the power cord into the AC socket of the projector.

2Reset the lamp timer.

While simultaneously holding down rMENU/HELP, pENTER and R on the projector, press oSTANDBY-ON on the projector.

“LAMP 0000H” is displayed, indicating that the lamp timer is reset.

AC socket

STANDBY-ON button

ENTER button

MENU/HELP button

R button

52