LC-NB2UW
34
LAMP REPLACEMENT INDICATOR
When the life of the Lamp of this projector draws to an end, the LAMP REPLACEMENT indicator lights yellow. When the
image becomes dark or the color of the image become unn atural, replacement of the Lamp is required.
LAMP REPLACEMENT
CAUTION
• For continued safety, replace with a lamp assembl y of the same type.
• Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the
projector can become very hot.
• Do not drop the lamp assembly or touch the glass bulb! The glass can shatter and may cause injury.
Follow these steps to replace the lamp assembly.
1
Turn off the projector and disconnect the AC plug. Allow the
projector to cool for at least 45 minutes.
2
Remove a screw with a screwdriver and remove the Lam p
Cover.
3
Remove 2 screws with a screwdriver and pull out the Lam p
Assembly by grasping the handle.
4
Replace the Lamp Assembly with new one and tighten 2
screws. Make sure that the Lamp Assembly is set properly.
And replace the Lamp Cover and tighten a screw.
5
Connect the AC Power Cord to the projector and turn the
projector on.
6
Reset the Lamp Replacement Monitor Timer (refer to the
section “Lamp Replacement Monitor Timer” below).
NOTE: Do not reset the LAMP REPLACEMENT MONITOR TIMER, when the lamp is not replaced.
ORDER REPLACEMENT LAMP
Replacement Lamp can be ordered through your dealer. W hen ordering the Lamp, give the following information to the
dealer.
• Model No. of your projector : LC-NB2UW
• Replacement Lamp Type No.: POA-LMP21J
(Service Parts No. 610280 6939)
Be sure to reset the Lamp Replacement Monitor Timer when the Lamp Assembly is replaced. When the Lamp
Replacement Monitor Timer is reset, the LAMP REPLACEM ENT indicator stops lighting.
1
Turn the projector on, and press the MENU button and the ON-SCR EEN MENU will appear. Press the POINT
LEFT/RIGHT buttons to select SETTING and press the SELECT butto n (refer to the page 31). Another
dialog box SETTING MENU will appear.
2
Press the POINT DOWN button and a red-arro w icon will appear. Move the arrow to Lamp age, and then press the
SELECT button. The message “Lamp replace monitor Res et?” is displayed.
3
Select to reset the Timer.
Do not reset the Lamp Replacement Monitor Timer, except af ter the lamp is replaced.