Appendix
Indicators and Projector Condition
Check the indicators for the projector condition.
The projector is operating normally..
| Indicators |
| Projector Condition | ||
POWER | LAMP/ | WARNING WARNING | LAMP | ||
|
| ||||
green | SHUTTER | TEMP. | FILTER | REPLACE |
|
red/blue | red | orange | orange |
| |
|
| ||||
|
|
|
|
|
|
|
|
|
|
| The projector is off. (The AC power cord is unplugged.) |
|
|
|
|
| ❖ |
| ✽ | ✽ | The projector is in | |
|
|
|
|
|
| button to turn on the projector. | ||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ❖ |
| ✽ | ✽ | The projector is operating normally. | |
|
|
|
|
|
| (The shutter is open) | ||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ❊ |
| ✽ | ✽ | The projector is operating normally. | |
|
|
|
|
|
| |||||
|
|
|
|
|
| (The shutter is closed) | ||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ✽ | ✽ | The projector is preparing for |
|
|
|
|
| ❖ |
| is being cooled down. The projector cannot be turned on until | |||
|
|
|
|
|
|
|
|
|
| cooling is completed and the POWER indicator lights green. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ❖ |
| ✽ | ✽ | The projection lamp is being cooled down in the Power | |
|
|
|
|
|
| |||||
|
|
|
|
|
| management mode. | ||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ❖ |
| ✽ | ✽ | The projector is in the Power management mode. | |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ✽ | ✽ | The projection lamp is being cooled down in the Shutter |
|
|
|
|
| ❊ |
|
| |||
|
|
|
|
|
|
| management mode. | |||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ✽ | ✽ | The projector is in the Shutter management mode. Press the | |
|
|
|
|
| ❊ |
|
| |||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ✽ |
|
| ✽ | The filter is scrolled using the FILTER button on the remote | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| control or the Filter control function in the setting menu. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| When the filter is being scrolled, the Filter replacement icon |
|
|
|
|
|
|
|
|
|
| and “Please wait...” message (Fig. 1) appear on the screen for |
|
|
|
|
|
|
|
|
|
| about 30 seconds. |
Fig..1 Filter replacement icon and “Please wait...” |
|
• • • on
❖• • • on (red)
❊• • • on (blue) • • • dim
❖• • • dim (red)
• • • blinking at the normal rate (approx. 1 second ON,
1 second OFF)
❊• • • blinking at the normal rate (blue and dim red) (approx. 1 second ON, 1 second OFF)
• • • off
✽• • • Differ according to conditions.
• • •blinking fast
(approx. 0.5 seconds ON,
0.5seconds OFF)
❊• • •blinking fast (blue and dim red) (approx. 0.5 seconds ON, 0.5 seconds OFF)
• • • blinking slow (approx. 2 seconds ON, 2 seconds OFF)
75