Off Timer

The Off Timer function allows the user to set the time in which the monitor will be in operation, called the “On Period” and automatically shifts the operation into the “Off Timer Mode” when the set “On Period” expires. The energy consumption of the monitor in the “Off Timer Mode” is as low as the one of the monitor in “PowerManger Mode 2” although no setting PC to operate the Off Timer function is required. The Off Timer will work while PowerManager is active, but there would be no advance notice before the monitor’s power switches off.

The default setting for the Off Timer is “disable”. For setup, please see below.

Setup Procedure

(1)Select the “Off Timer” icon and press the Enter button to display “Off Timer” select menu.

(2)Select “Enable” and press the enter button.

(3)Press the right/left key to adjust how long (1 to 23 hours) the monitor should be in the “On Period”. Then, press the enter button to return to the “others” menu.

(4)Select the “Exit” icon and push the Enter button to exit the ScreenManager.

Advance notice (beep with LED flashing green) will be given 15 minutes before the monitor automatically will enter the “Off Timer Mode”. To turn off the beeper, see page 36.

38 2 ADJUSTMENTS & SETTINGS USING THE SCREENMANAGER

Page 38
Image 38
Eizo T960 user manual Off Timer, Setup Procedure