Design Spot 250 Pro™
©Elation Professional® 12 Design Spot 250 Pro
equivalent). Please remember there is only one way to insert the lamp and the lamp
should fit completely in the lamp socket.
5. Once the lamp has been inserted into the socket, gently slide the socket assembly
back into place and secure with the two Phillips screws.
6. Always be sure to optimize the lamp after lamp replacement.
Do not operate this device with open cover
Lamp Optimization
The lamp orientation and optimization must be adjusted after every lamp change. This
procedure centers the lamp in the reflector. Proper optimization will increase lamp life and
ensure a bright crisp output. Improper optimization may add a yellow tint to the lamp output
and reduce intensity. The minimum deviation amount is 1.0mm. Running the fixture within a
lower deviation can cause damage to the lamp and/or lens.
The Design Spot 250 Pro™ lamp holder is aligned at the factory. However, due to slight
imperfections in all lamps, fine adjustments will improve light performance. Please follow the
procedure below for proper lamp optimization:
1. Using either a DMX controller or the control panel on the unit (see “LAMP ADJUST” in
the fixture menu on page 32), strike the lamp and focus the light on a flat surface
(beam open, white, no gobo, no effect).
2. Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws
labeled 1, 2, and 3 as illustrated on the next page. Turn one screw at a time to drag
the hot-spot diagonally across the projected image. If you cannot detect a hot-spot,
adjust the lamp until the light is even.
3. To reduce a hot-spot, pull the lamp in by turning all three screws clockwise a 1/4-turn
at a time until the light is evenly distributed.
4. If the light is brighter around the edge than it is in the center, or if light output is low,
the lamp is too far back in the reflector. "Push” the lamp out by turning each of the