Design Spot 250 Pro™
©Elation Professional® 25 Design Spot 250 Pro
Where “XXXX ”represents the total number of running hours. This time is none
destructive and will remain in the fixtures memory indefinitely.
Total Lamp Time
This function tracks the total number of lamp running hours. Where “XXXX”
represents the number of hours the lamp has been running. This counter should be
reset after every lamp change.
Lamp Off Time
This function displays the running time of the lamp from the last power on. The
display shows “XXXX”, where “XXXX” represents the number of hours the lamp has
been running since it was last struck. This counter is automatically reset after every
power-on.
Clear Lamp Time
This function resets the lamp “ON” time to zero. Please reset the lamp “ON” time at
every lamp replacement. This procedure tracks the lamp running time so the lamp
can be replaced at the end of it’s recommended duty cycle.
• Select “Clear lamp time” in the system menu.
• The LCD will display “ON” or “OFF.” Were “ON” will reset the lamp time.
• Press enter to confirm.
• Press the Mode/Esc-button to return to the main menu.
8.2.2. Temperature Info.
This function will detail different temperatures associated with the fixture in either
Celsius or Fahrenheit.
Base Temp – This function will display the internal base temperature of the fixture
in real time.
Head Temp – This function will display the internal head temperature of the fixture
in real time.