Design Spot 250 Pro™
©Elation Professional® 27 Design Spot 250 Pro
“XX M” Where XX represents the hold time before lamp shut down.
8.3.6 Lamp On at Temp.
The fixture is designed to shut the lamp off when an excessive temperature is sensed
inside the head by the on-board CPU. The lamp is shut down to prevent damage to the
lamp and avoids possible internal damage to the head. This function sets the minimum
temperature for lamp re-strike after the lamp has been automatically shut off.
8.3.7 Lamp Off at Temp.
The fixture is designed to shut the lamp off when an excessive temperature is sensed
inside the head by the on-board CPU. The lamp is shut down to prevent damage to the
lamp and avoids possible internal damage to the head. This function sets the maximum
internal operating temperature of the head before the lamp will automatically be shut
down. This function can be set to activate at an internal temperature between 80° C and
139° C. Inside temperatures below 90° C are not critical. Temperatures above 90° C
should lead to the lamp being switched off. Please note that the outside temperature
should not exceed 45° C.
8.4 Personality:
8.4.1 Status setting
Address via DMX - This function allows the DMX address to remotely be adjusted
from a DMX console. This setting requires special settings for both the controller and
the fixture. RDMX is on by default. For operational instructions please see Section
10/Page 33 of this manual “Remote DMX addressing.”
No DMX Status – This function dictates how the fixture will function if it looses DMX
signal during normal operation. The default function is set to hold, in which the
fixture will lock into the last DMX signal it received and remain in that position until it
is turned off or begins receiving a new DMX signal. If the fixture is turned on
without any DMX signal, the fixture will automatically go in to sound-active mode.
Available settings are: “Close” – Shutter flags will close. “Hold” – Fixture will remain