GAS COOKTOP INSTALLATION INSTRUCTIONS
4
ACB
Figure 3 – CABINET DESIGN
To eliminate the risk of
burns or fire from reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. If
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 7"
(17.8 cm) beyond the bottom of the
cabinets.
18" (45.7 cm)
Min.
2" (5.1 cm) min. distance
between rear edge of
cutout and nearest
combustible surface
above countertop
13" (33 cm) max. depth
for cabinet installed above
cooktop
30" (76.2 cm) min.
clearance between
the top of the
cooking platform and
the bottom of an
unprotected wood or
metal cabinet.
24" (61 cm)
30" (76.2 cm) Min.
Clearance Between the
Top of the Cooking
Platform and the Bottom
of an Unprotected Wood
or Metal Cabinet
24" (61 cm) Min.
when Bottom of Wood
or Metal Cabinet is
Protected by Not Less
Than 1/8" Flame
Retardant Millboard
Covered With Not Less
Than No. 28 MGS
Sheet Steel, 0.015"
(0.4 mm) Stainless
Steel, 0.024" (0.6 mm)
Aluminum or 0.020"
(0.5 mm) Copper
It is not recommended to use
drawer underneath cooktop.
MODEL A B. Minimum C. Minimum
Clearance from Clearance from
Left Side Right Side
36" (91.4 cm) 36" (91.4 cm) 9" (22.9 cm) 9" (22.9 cm)
30" (76.2 cm) 30" (76.2 cm) 5" (12.7 cm) 5" (12.7 cm)