38 www.aeg.com

50 mm

60 mm

60 mm

 

50 mm

A

A

 

B

1.Set the correct height and area for the appliance before you attach the anti-tilt protection.

2.The anti-tilt protection has two parts (A+B). You can find the anti-tilt pro- tection (B) on the right or left side of the rear wall of the appliance (See fig. 1). You must install the anti-tilt protec- tion (A) on the wall. The distance of the hole of the anti-tilt protection (A) from the floor is about 816 mm. Make sure you install the anti-tilt protection

(A) at the correct height. Screw it into the solid material or use applicable reinforcement.

3.Check that the anti-tilt protection fits minimum 20 mm into the hole in rear wall of the appliance (B) when you push the appliance (See fig. 2). Put the appliance in the middle of the space between the cupboards. If the space is larger than the width of the appliance, you must adjust the side measurement. Make sure that the sur- face behind the appliance is smooth.

ELECTRICAL INSTALLATION

The manufacturer is not responsi- ble if you do not follow the safety precautions from the chapter "Safety information".

This appliance is supplied without a main plug or a main cable.

Applicable cable types: H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05 V2V2-F (T90), H05 BB-F.

COVERING TERMINAL BOARD

The recommended cross-section area is six square millimetres (6 mm²).

When you refit the mains terminal cover, make sure that the lower tabs are located inside the bottom edge of the aperture, before you fix the two screws into the top edge of the mains terminal cover.

Make sure that the cover is securely fas- tened.

To open the cover of terminal board obey the procedure in op- posite sequence.

Page 38
Image 38
Electrolux 49332I-MN user manual Electrical Installation, Covering Terminal Board