Electrolux E36GF75GPS, E36GF76GPS, 318201761E30GF74GPS manual Conversion To LP Gas

Models: 318201761E30GF74GPS E36GF75GPS E36GF76GPS

1 30
Download 30 pages 61.54 Kb
Page 22
Image 22
22 Conversion To LP Gas

22 Conversion To LP Gas

INSTRUCTIONS FOR CONVERTING RANGE FROM NATURAL GAS TO LP GAS

Determine the combination of top burners that are featured on your range. Identify the parts you need from this kit to complete the L.P. conversion. When burners are converted from natural to L.P. the BTU ratings are as follows:

Top burner

15,000 BTU L.P. Gas

 

Oven Burner

22,000 BTU L.P. Gas

 

Oven Broiler

16,500 BTU L.P. Gas

 

Griddle

 

18,500 BTU L.P. Gas

 

 

 

 

Quantity

Part Description

Notes

1

LP Conversion kit label

 

1Instruction for converting range to LP Gas

1LP Conversion Label

6Orifice - Top Burner, #58

6Orifice - Simmer Burner, .46mm

1Orifice - Oven Burner, #55

1Orifice - Oven Broiler, #56

1Orifice - Griddle, #55

6Main burner bypass jet, blue ring

6Simmer burner bypass jet

*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at a rate of 4 percent for each 1000 ft. above sea level

IMPORTANT

After replacing the natural gas to LP orifices, be sure to keep the original factory installed natural gas orifices for future range conversion back to natural gas. The factory orifices are marked with the following: Top Burners 165; Oven Burner 226; Oven Broiler 185; Griddle 206; Main Burner Bypass Jet; Simmer Bypass Jet