12

C TECHNICAL DATA

C1 Main technical characteristics

MODEL 44” (208V) 44” (240V) 66” (208V) 66” (240V)

MAIN TECHNICAL DATA

Power supply Electric Electric Electric Electric
Power supply voltage V 208 3PH 240 3PH 208 3PH 240 3PH
Frequency Hz 60 60 60 60
Max. power. absorbed with boiler
( rise 56 °C / 100 °F)
kW 44.7 44.7 45.0 45.0
Max. power. absorbed with boiler
( rise 39 °C / 70 °F)
kW 38.7 38.7 39.0 39.0
Max. power. absorbed with boiler
( rise 22 °C / 40 °F)
kW 32.7 32.7 33.0 33.0
Max. power. absorbed without boiler kW 20.7 20.7 21.0 21.0
Max. current. absorbed with boiler
( rise 56 °C / 100 °F)
A 128.3 112.7 130.6 115.2
Max. current. absorbed with boiler
( rise 39 °C / 70 °F)
A 111.6 98.3 113.9 100.8
Max. current. absorbed with boiler
( rise 22 °C / 40 °F)
A 95.0 83.9 97.3 86.4
Max. current. absorbed without boiler A 61.7 55.0 64.0 57.5
Supply water pressure kPa/bar/PSI
150..700 / 1.5..7
/
22..102
150..700 / 1.5..7
/
22..102
150..700 / 1.5..7
/
22..102
150..700 / 1.5..7
/
22..102
Hot water supply temp. with boiler **
( rise 56 °C / 100 °F)
°C/°F 27 / 80 27 / 80 27 / 80 27 / 80
Hot water supply temp. with boiler
( rise 39 °C / 70 °F)
°C/°F 44 / 110 44 / 110 44 / 110 44 / 110
Hot water supply temp. with boiler
( rise 22 °C / 40 °F)
°C/°F 60 / 140 60 / 140 60 / 140 60 / 140
Hot water supply temp. without boiler °C/°F 90 / 194 90 / 194 90 / 194 90 / 194
Concentration of chlorides in water ppm < 20 < 20 < 20 < 20
Electric conductivity of water μS/cm < 400 < 400 < 400 < 400
Supply water hardness °fH /°dH/
ppm CaCO3

14 / 8 / 140 14 / 8 / 140 14 / 8 / 140 14 / 8 / 140

Rack loading/feed
RH machine
LH machine
From right to left
From left to right
From right to left
From left to right
From right to left
From left to right
From right to left
From left to right
No. speeds 2 2
22
Capacity speed 1 racks/h 100 1 00 100 100
Capacity speed 2 racks/h 200 2 00 200 200
Water consumption l/h - gal/h 300 - 79.3 300 - 79.3 315 - 83.2 315 - 83.2
Equivalent sound pressure level Leq
(1)
dB(A) < 70 < 70 < 70 < 70
Minimum Supply - Circuit Ampacity
Supply Terminal box ( Boiler ) (2)
A67586758
Minimum Supply - Circuit Ampacity
Supply Terminal box ( Machine ) (2)
A66606660
Maximum overcurrent protective device
Supply Terminal box ( Machine ) (2)
A80708070
Net weight lb/kg 1012 / 459 1012 / 459 1268 / 575 1268 / 575
Shipping weight lb/kg----
Shipping width lb/kg
--
--
Shipping height lb/kg
--
--
Shipping depth lb/kg
-
-
--

PREWASH

tank capacity l/gal - - 45/ 11.9 45/ 11.9
temperature °C/°F - - max 40 / 104 max 40 / 104
pump delivery l/min - gal/min - - 180 - 57.5 180 - 57.5
pump power kW - - 0.37 0.37
current absorbed by pump A - - 2.5 2.5
tank heating elementkW----

WASH

tank capacity l/gal 100/ 26.4 100/ 26.4 100/ 26.4 100/ 26.4
temperature °C/°F 71..78
/
160..172 71..78
/
160..172 71..78
/
160..172 71..78
/
160..172
pump delivery l/min - gal/min 450 - 118.9 450 - 118.9 450 - 118.9 450 - 118.9
pump power kW 1.9 1.9 1.9 1.9
current absorbed by pumps A 6.2 6.2 6.2 6.2
tank heating element kW 9.0 + 9.0 9.0 + 9.0 9.0 + 9.0 9.0 + 9.0