Emerson 400508-02 installation manual Basic Installation Notes, Mechanical Installation

Models: 400508-02

1 60
Download 60 pages 56.07 Kb
Page 15
Image 15
Installation

Installation

Basic Installation Notes

You are required to follow all safety precautions during start-up such as providing proper equipment grounding, correctly fused power and an effective Emergency Stop circuit which can immediately remove power in the case of a malfunction. See the “Safety Considerations” section for more information.

Mechanical Installation

The FM-3 detects and verifies the drive serial number when its attached to an E Series drive. If an FM-3 is moved from one drive to another, it will detect the difference in serial numbers and generate an Invalid Configuration fault.

Two aligning tabs, a locking latch and a 100-pin connector are used to attach the FM-3 to an E Series drive. All electrical connections between the FM-3 and the E Series drive are accomplished with the single connector located on the rear of the FM-3.

1

Grip the FM firmly on each side.

Continue pressing the FM against the drive until the latch clicks into the slot on the top of the drive.

4

3

Gently press the FM against the drive, aligning the 100-pin connector.

2

Insert the aligning tabs into the slots on the drive.

Figure 3: Attaching the FM-3 to an E Series Drive

Caution

Do not attach or detach the FM-3 when power is applied to the drive. It could cause drive instability.

3

Page 15
Image 15